Bosch 1 687 001 612 Instrucciones De Manejo página 5

Juego de ampliación 180mpa
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

1 687 001 612
..2.
Converting the high-pressure rail
9.
Close off the orifice on the opposite side
of the high-pressure relief valve with the
hexagon bolt (item 8).
10.
Secure the high-pressure rail in the holder
again and re-connect (see Fig. 1).
Fig.: 3
11.
Connect PVC hose (item 11) to the hose
manifold and route it to the test oil tank via
the recesses on the EPS cover.
1 687 001 612
Best. -Nr
.
Typ
.
Serien-Nr.
.
XXX
FD
Pmax = 180 MPa
Made in Germany
Fig.: 4
12.
Apply new rating plate to control device.
Robert Bosch GmbH
11
Best. -Nr
1 687 001 845
.
CRS845
Typ
.
Serien-Nr.
.
FD
XXX
Pmax = 160 MPa
Made in Germany
3.
Software configuration
3.1
Installing the system software
i
Minimum requirement for the system software
for 180 MPa extension set: Version  2.2.
i
Instructions on installing the system
software are available in the EPS945-PE/
VE/CR program description (order number:
1 689 979 859), chapter 14.1 "Installation of
KMA system software EPS945".
3.2
Updating the firmware
i
Instructions on updating the firmware are
available in the EPS945-PE/VE/CR program
description (order number: 1 689 979 859),
chapter 14.2 "Firmware update".
3.3
Configuring the software
Procedure
1.
In the system software, select softkey <F7>
in the "main menu" dialog box.
2.
Enter password:
confirm.
The "Configuration" dialog box will
appear.
3.
Call item "Test mode" in the "System"
menu by pressing <F12>.
The "Test type" dialog box will
appear.
4.
In the "Maximum rail pressure setting"
field, select 180 MPa.
5.
Confirm selection with <F12>.
6.
Confirm security prompt with <F4>.
7.
Confirm selection with <F12>.
8.
Exit the "Configuration" dialog box by
pressing Esc.
The system will initialize the
connected devices.
"
The 180 MPa extension is active.
en 
and press <F12> to
eps
1 689 978 501 (2006-01-09)
Tabla de contenido
loading

Tabla de contenido