Safety Notes; Technical Data; Replacement Parts - Grohe EUROECO COSMOPOLITAN E 36 274 Manual De Instrucciones

Ocultar thumbs Ver también para EUROECO COSMOPOLITAN E 36 274:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
GB

Safety notes

• Installation is only possible in frost-free rooms.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.

Technical data

• Voltage supply:
6V lithium battery type CR-P2
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (7 - 20cm adjustable):
• Type of fitting protection:
Thermal disinfection possible.
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• Battery discharged
(indicator lamp lights up continuously)
Undesired water
• Sensor system detection zone set too high
flow
for local conditions
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Mousseur dirty
• Filter upstream of solenoid valve dirty
Functions, programme selection,
see technical product information,
www.grohe.com/tpi/euroeco-ce
Installation
, see fold-out page I - II.
Flush pipes thoroughly before and after
60 s
installation (observe EN 806)!
Open hot and cold water supply and check that
1 s
connections are watertight.
16cm
Maintenance
IP 59K
, see fold-out page II.
• Shut off water supply.
• Disconnect voltage supply.
• Inspect and clean all components and replace if
A
necessary.
2
Batteries which are almost discharged are displayed
2500 V
by a flashing indicator lamp in the sensor system.
100 °C

Replacement parts

see fold-out page I (* = special accessories)
,
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Reduce range using remote control (special
accessory, prod. no.: 36 407)
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
2
Tabla de contenido
loading

Tabla de contenido