MODEL
VDD5300
VDD5360
VDD5450
VDD5480
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualifi ed person(s) in accordance with all applicable codes
and standards, including fi re-rated construction codes and
standards.
4. Suffi cient air is needed for proper combustion and exhausting
of gases through the fl ue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fi re, use only metal ductwork.
8. Do not install this product with the activating switch directly
behind a burner or element. Minimum distance between the
switch and the edge of the burner should be 4 inches.
9. Loose-fi tting or hanging clothing should never be worn when
operating this appliance. They may be ignited by burners/
elements on cooktop.
10. Children should not be left alone or unattended in the area
where this appliance is in use.
11. This unit must be grounded.
12. To reduce the risk of fi re or electric shock, it is recommended
that the downdraft be installed with a dedicated circuit separate
from the appliance.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking fl aming foods.
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or fi lter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
WIDTH
BLOWER (purchased separately)
30" W.
VDVI600 Interior or VDVE900 Exterior
36" W.
VDVI600 Interior or VDVE900 Exterior
45" W.
VDVI600 Interior or VDVE900 Exterior, VDVE1200 Exterior
48" W.
VDVI600 Interior or VDVE900 Exterior, VDVE1200 Exterior
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fi tting lid, cookie sheet, or
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a
4. Use an extinguisher ONLY if:
* Based on "Kitchen Fire Safety Tips" published by NFPA.
CAUTION
1. TO REDUCE THE RISK OF FIRE OR INJURY, DO NOT INSTALL
2. For indoor use only.
3. For general ventilating use only. Do not use to exhaust
4. To avoid motor bearing damage and noisy and/or unbalanced
5. Clean fi lters and grease-laden surfaces frequently.
6. Do not repair or replace any part of this appliance unless
7. Please read specification label on product for further
8. To reduce the risk of fi re and electric shock, install this downdraft
9. To reduce the risk of fi re and electric shock, install this downdraft
Save this manual for Electrical Inspector
2
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the fl ames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
violent steam explosion will result.
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fi re is small and contained in the area where it started.
C. The fi re department is being called.
D. You can fi ght the fi re with your back to an exit.
!
WITH COOKING PRODUCTS THAT HAVE A GRIDDLE.
hazardous or explosive materials and vapors.
impellers, keep drywall spray, construction dust, etc. off power
unit.
specifi cally recommended in this manual. All other servicing
should be done by a qualifi ed technician.
information and requirements.
only with blower models shown below. Other blower models
cannot be substituted. (Blowers sold separately).
Flex Blower Model VDVI600
Exterior Blower Models VDVE900, VDVE1200
only with non-ducted recirculating kit - ARKD.