9 (Optional) Set a static IP address for the Control Port and/or Feature Port.
* Note: For detailed information on this step and additional screen samples, see "Modify Network Settings"
on pages 27 to 29.
a) At the
TCP/IP configuration is performed in the CentOS Network Manager TUI (text-based user interface). The
system will display the Network Manager menu, for example:
b) Select/highlight
c) In the next screen, select/highlight the port you wish to configure and press
d) With the Edit Connection screen for the selected port on display, add the appropriate IPv4 port IP address
in the format xxx.xxx.xxx.xxx/xx, where the last two digits (after the forward slash) identify the network mask
bits for the IP address.
Also, add the gateway, and DNS IP addesses in the format xxx.xxx.xxx.xxx.
* Note: In order to avoid a service interruption, do not modify any of the other fields in the
Edit Connection screen. In particular, do NOT modify the data in the Profile Name and
Device fields.
* Note: The Feature Port IP address MUST be on a different subnet than the Control Port IP
address.
e) When you are finished with network configuration for the selected port, select/highlight
bottom right of the Edit Connection screen and press
f) Repeat steps (c) to (e), as required, to complete configuration for the second port.
g) When you are finished with port configuration, select/highlight
selection screen and press
return to the
* Note: Review the configuration data for each port carefully before you confirm the settings. Ensure each
of the addresses was entered correctly.
* Note: You may also edit the host name from the Network Manager menu, if desired. See "Modify the
Server Host Name" on pages 30 to 31 for further information. Avoid using spaces or special charac-
ters, such as ?, -, etc., in the host name.
22
prompt, type
and press
and press
to return to the Network Manager menu. To exit the Network Manager and
prompt, select
.
.
.
and press
.
.
at the bottom right of the port
at the