Function Of Control Terminals; Standard Control Wiring - BONFIGLIOLI Vectron Agile Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Function of control terminals

Standard control wiring

X13:
1
2
3
4
> 4k7
X12:
1
2
3
4
X11:
1
2
3
4
5
IND:
digital input
MFI:
multifunction input
OUTD
digital output
OUT2D:
digital output 2
MFO1:
multifunction output
Run Sig.
execution message
Act. Speed:
actual speed
Speed ref:
setpoint speed
Mot.
motor temperature
Sys
CAN-systembus
Enable:
release
FixedFr.
fixed frequency
Dataset
Dataset
Relay output
relay output fault message
Memory card:
slot for optional memory card
Mode:
operation mode for X11.6
X:
terminal strip
Thermal contact evalu-
ation X12.4
P570
0- off (default)
1- Warning
2- Error switch
off
Agile
Quick Start Guide
6 digital inputs, 2 of them for
Enable
1 digital input/ output
2 multifunction inputs:
digital/analogue
1 digital output
1 multifunction output:
digital/analogue/frequency
5
6
Act.
Speed
5
6
Relay output
Fault Message
X10:
6
1A DC / 24V
3A AC / 240V
Data set change-over
X11.6
Selection
0
DS1
1
DS2
Switching frequency
X12.1
Selection
0
0 Hz (P480)
1
10 Hz (P481)
X13.1
DC 24 V input
X13.2
GND forX13.1
X13.3
Digital input. Input 2 for enable. Contact
opened: output disabled, motor coast to
a standstill. Contact closed (together
with X11.3): normal operation.
X13.4
DC 10 V output
X13.5
Digital output. Run signal. Indicates out-
put of frequency when enable and start
command applies.
X13.6
Multifunction output. Default: analogue.
Voltage signal proportional to actual
speed. 10 V at 50 Hz,0V at 0Hz.
X12.1
Digital input.
Data set change-over together with
X11.6.
X12.2
Digital input. Error acknowledgment.
X12.3
Multifunction input: digital/analogue.
Default: analogue voltage input. Refer-
ence speed. 50 Hz at DC 10 V, 3.50 Hz at
DC 0 V.
X12.4
Multifunction input: digital/analogue.
Default: digital input. For connection of
motor thermal contact. Set P570.
X12.5
CAN High
X12.6
CAN Low
X11.1
DC 24 V output
X11.2
GND for X11.1
X11.3
Digital input. Input 1 for enable. Contact
opened: output disabled, motor coast to
a standstill. Contact closed (together
with X13.3): normal operation.
X11.4
Digital input. Start clockwise.
X11.5
Digital input. Start anticlockwise.
X11.6
Digital input/output. Default: input. Data
set change-over together with X12.1.
Observe the technical data in the
42
1 voltage input DC 24 V
2 voltage outputs,
DC 10 V and DC 24 V
1 relay output
Communication-
interface CAN
Systembus connection.
Refer to the separate man-
ual.
manual.
05/2019
Tabla de contenido
loading

Tabla de contenido