Automatic shut-off takes too long or there is continuous flow
(Fig. K):
• Clean the inside of the delay case
and clean the calibrated groove
• Check that the lip seal
• AB cartridge: remember to replace the spring
Dripping or a constant trickle (Fig. K):
• Clean the seat
• AB cartridge: remember to replace the spring
Fig. K: ³ = standard cartridge
Parts of the cartridge:
= seat
= valve holder
Beware: do not grease the inside of the mechanism.
Mixer: regularly check (as often as necessary) the temperature
selector and the mixer's two internal seats on which the mixing key
turns. Replace as necessary.
NB: Check that the seals between wall plate and the wall and
between the wall plate and the mixer/tap/valve are watertight
at least once a year, and more often if necessary. Replace as necessary.
MAINTENANCE AND CLEANING
• Cleaning chrome: do not use abrasive, chlorine or any other
acid-based cleaning products. Clean with mild soapy water using
a cloth or a sponge.
• Frost protection: drain the pipes and operate the mixer/tap/valve
several times to drain any remaining water.
After Sales Care and Technical Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com
and seat
or replace if damaged.
= lip seal
= spring
using a clean, dry cloth;
with a non-metallic, sharp point.
are in good condition.
.
.
· = AB cartridge
= calibrated groove
= delay case