Toshiba RAV-GP1101AT8-E Manual Del Usuario página 86

Ocultar thumbs Ver también para RAV-GP1101AT8-E:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
How to wire
1.
Connect the connecting wire to the terminal as
identified with their respective numbers on the
terminal block of the indoor and outdoor units.
2
H07 RN-F or 60245 IEC 66 (1.5 mm
or more)
2.
When connecting the connecting wire to the outdoor
unit terminal, prevent water from coming into the
outdoor unit.
3.
Secure the power supply wire and indoor/outdoor
connecting wires using the cord clamp of the
outdoor unit.
4.
For interconnecting wires, do not use a wire joined
to another on the way.
Use wires long enough to cover the entire length.
5.
Wiring connections differ in conformance to
EMC standards, depending whether the system
is single, twin or triple. Connect wires according
to respective instructions.
CAUTION
• Fuse must be used in installation for the power supply
line of this air conditioner.
• Incorrect/incomplete wiring may lead to an electrical
fire or smoke.
• Prepare an exclusive power supply for the air
conditioner.
• This product can be connected to the mains power.
Fixed wire connections:
A switch that disconnects all poles and has a contact
separation of at least 3 mm must be incorporated in
the fixed wiring.
EN-169
- 85 -
Wiring diagram
* For details on the remote controller wiring/installation, refer to the Installation Manual enclosed with the remote
controller.
Single system
Remote controller
Remote controller
wiring
A B
Indoor side
1
2
3
Indoor/Outdoor
connecting wires
1
2
3
Outdoor side
L1
L2 L3
N
Power supply
Simultaneous triple system (GP160 only)
Remote controller
Remote controller
Remote controller
inter-unit wiring
wiring
A B
Indoor side
Indoor side
1
2
3
Indoor/Outdoor
connecting wires
1
2
3
Outdoor side
L1 L2 L3 N
Power supply
* Use 2-core shield wire (MVVS 0.5 to 2.0 mm
simultaneous triple systems to prevent noise problems. Be sure to connect both ends of the shield wire to earth
leads.
* Connect earth wires for each indoor unit in the simultaneous twin and simultaneous triple systems.
Simultaneous twin system
Remote controller
Remote controller
wiring
A B
Indoor side
1
2
3
Indoor/Outdoor
connecting wires
1
2
3
Outdoor side
L1 L2 L3 N
Power supply
Remote controller
inter-unit wiring
A B
A B
Indoor side
1
2
3
1
2
3
Indoor power
Indoor power
inter-unit wiring
inter-unit wiring
2
or more) for the remote controller wiring in the simultaneous twin and
Remote controller
inter-unit wiring
A B
Indoor
side
1
2
3
Indoor power
inter-unit wiring
EN-170