16. WARNING LABEL: "Caution – Class 3B laser. Laser Radiation when open. Avoid exposure to beam."
17. WARNING LABEL: "Laser Aperture"
18. LASER WARNING SIGN: warns against a potentially dangerous laser when not used by skilled
operators.
19. WARNING LABEL: "Laser Radiation. Avoid exposure to beam. Class 3B laser product"

OVERHEAD RIGGING

 Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
 Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
 Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
 The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
 Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
 Always use a certified safety cable that can hold 12 times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
 The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
 Don't cover any ventilation openings as this may result in overheating.
 The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
CAUTION EYE DAMAGE: Always position the laser in a way that prevents the
audience from looking directly into the laser beams. The installation should assure that
the beam will not strike the audience.
HOW TO SET UP AND CONTROL THE UNIT
MUSIC INPUT SENSITIVITY:
The unit works to rhythm of the beat when used in standalone or master/slave mode
To set the input sensitivity, follow these steps:
 Press the FUNC-button until the display shows "S 0" ..."S 9"
 Press the ENTER-button to confirm your choice.
JB SYSTEMS
®
USER MANUAL
5/75
SMOOTH SCAN-3 LASER
ENGLISH
 Use DOWN and UP button to select a value between "S 0" (very low sensitivity) and "S 9" (high
sensitivity).
 Once the mode is selected, press the ENTER button save it.
You can operate the unit in 5 ways:
1) MUSIC CONTROLLED MODE:
The laser runs a preprogrammed sequence to the rhythm of the music. Select this mode when only 1 laser
is used (standalone) or when the laser is placed as the first (master) unit in a chain with several units.
 Press the FUNC-button until the display shows one of the following: Aut, Aup, 17C, 1C, Sla or REM.
 Now use the UP or DOWN buttons to select:
Sop
(Sound activated random show, containing pattern and grating effects)
o
o
Sou
(Sound activated shows in RGY colors)
o
So1
(Sound activated show in red color)
So2
(Sound activated show in green color)
o
So3
(Sound activated show in yellow color)
o
 Press the ENTER-button to confirm your choice.
You can connect several LASERs together: just put the first unit of the chain in one of the sound activated
effect modes and all other units in "Slave mode" (display shows "SLA") to make them all work in perfect
sync!
Note: When no music is detected, the laser output will be shut off (blackout).
2) FULL AUTOMATIC MODE:
The laser automatically runs a preprogrammed sequence. Select this mode when only 1 laser is used
(standalone) or when the laser is placed as the first (master) unit in a chain with several LASERs.
 Press the FUNC-button until the display shows one of the following: Sop Aut, Aup, 17C, 1C, Sla or
REM.
 Now use the UP or DOWN buttons to select:
Aut
(Automatic shows in RGY colors)
o
Au1
(Automatic shows in red color)
o
o
Au2
(Automatic shows in green color)
o
Au3
(Automatic shows in yellow color)
Aup
(automatic random show, containing pattern and grating effects)
o
 Press the ENTER-button to confirm your choice.
The laser automatically runs a preprogrammed sequence.
You can connect several SMOOTH SCAN 3 LASERs together: just put the first unit of the chain in one of
the automatic effect modes and all other units in "Slave mode" (display shows "SLA") to make them all
work in perfect sync!
3) SLAVE MODE:
The laser follows the instructions given by the first Smooth Scan 3 laser (master) in the chain.
 Connect the DMX input of the laser to the DMX output of the previous laser in the chain.
 Press the FUNC-button until the display shows "SLA"
 Press the ENTER-button to confirm your choice.
You can connect several lasers together. Please put the first unit of the chain in "Music or automatic
mode" and all other units in "Slave mode" (display shows "SLA" to make them all work in perfect sync!