SPECIFICATIONS
Model
Max seal length
Max Seal Thickness
Max Circum
Voltage
Watts
Weight
Dimensions
OPERATING ISSUE
Sealer is not sealing.
The film is not cutting through.
PAGE 3 OF 9
OPERATING INSTRUCTIONS CONTINUED
AIE – 1818L
18" x 18"
100 ga shrink film
36"
110V
1000 w
54 lbs
27" x 21.75" x 7.25"
TROUBLESHOOTING
HELPFUL INFORMATION
1. Always keep the sealing platform clean. Particular
care should be taken to remove any residue from
the Teflon
tape.
®
2. Do not clean the sealing platform with anything wet
while sealing machine is plugged into outlet.
3. It is important to replace the element wire with the
one designed for this machine. Using different wires
can damage the transformer.
4. Occasionally check the condition of the upper
silicone rubber pads for wear or burns. A poor
silicone rubber pad will affect the quality of the seal.
RECOMMENDATIONS
Check if the power switch is turned ON.
Check if the fuse is blown. Fuse is located on the back
of unit, left of the power cord. Unscrew the black cap to
reveal the fuse (15 amp). Check fuse with fuse tester or
multimeter. Replace fuse if bad.
If the lamp indicator light is functioning:
• The timer might be faulty. Contact Uline Customer
Service at 1-800-295-5510.
• The element (heating wire) is broken. Refer to
replacement instructions on previous page.
If the lamp indicator is not functioning:
• Check if the power switch is on.
• Check if fuse is blown. See instructions above.
Check if the upper silicone rubber and the sealing
element are parallel with each other.
1-800-295-5510
uline.com
0521 IH-2378