ELECSUN2 10A - 12/24V series controller has four
working modes. Table of settings is as below:
1.Purely light-operated (0): When there is no sunlight, the
light intensity will fall to the starting point. The controller
will affirm the starting signal after a delay of 10 minutes.
Load will be opened as per set parameters to start
working. When there is sunlight, the light intensity will
rise up to the starting point. The controller will close
output after confirming closing signal in a delay of 10
minutes and the load will stop working.
2.Light-operated + time-controlled (1~4.): Starting
process is same to that of pure light control. The load will
automatically close when it works to the preset time. Set
time will be 1 to 14 hours. At the same time can setting
the lighting time in the morning, this function just can use
under the Light-operated and time-controlled mode.
3.Manual mode (5.): Under this mode, users can control
the load-on and load-off by key-press no matter day or
night. This mode is suitable to occasions in need of
special loads or for debugging.
Long-term On
Long-term Off
Fast twinkling
excessively
discharged
Load is open
Load is close
Overload protection
or short circuit
protection or unusual
voltage.