INSTALLATION AND WIRING

1. Installation of controller should be stable and
dimensions are as follows:
Overall dimension: 124.7×69.4×34(mm)
Installation dimension: 112.4×54(mm)
Installation hole diameter: 3.6(mm)
2. ELECSUN2 10A - 12/24V series controller can work
under 12V or 24V voltage. Please connect the storage
battery at first, controller will work after recognize the
battery volt automatically. If 12V, the digital tube will
shows "0.".If 24V, the digital tube will shows "1.".
3. First, connected to the storage battery: Pay attention
to the "+" and "–", in case of reverse connection. If
connected well, the indicator light will be on. Otherwise,
please check the connection.