CONTROL PANEL NE269
GB
CONTROLS:
Push button with warning light for turning
INTERNAL LIGHTS on or off (*)
Push button with warning light for turning
EXTERNAL LIGHTS on or off (*)
(*) the indication of the active load is also appears on the display with the symbol.
SCREENS:
The main screen always shows the date, time, service battery voltage, internal and external temperatures. (If there is no
temperature probe the temperature it does not come visualized). If the temperature probe is faulty the wording "---" will
appear. Display contrast can be adjusted by turning the P1 located on the back of the panel.
This symbol appears when there is a main.
This symbol appears when a fuse on the
This symbol appears when the vehicle engine is running and the parallel batteries is active
This symbol appears when there is an error communicating with NE185 shunt.
This symbol indicates that the alarm clock is enabled with related time. The alarm clock rings at the
pre-set time for 1 minut every 10 minutes; press any button to stop it ringing.
Repeatedly pressing this Key for viewing the voltage of the battery service, the level of drinking
water in tank S1 and the level of recovery tanks R1-R2..
If the tank is wrongly connected, the display will show "- - -".
The screen remains active for approx. 30 seconds.
PROGRAMMING:
Press this key to viewing the programming menu.
Use the arrow keys to change pages. Press the enter key (
be edited.
Use the arrow keys to increase or decrease the selected value, and the cancel (
the value.
The pages available are:
-Regulation of time and date
-Regulation and enabling of alarm clock.
-Alarm enabling tanks: drinking water tank is empty, recovery tanks are full.
This situation generates an alarm that sounds intermittently for 5 seconds. At the same time the display
shows the tank-viewing window with the symbol
-Alarm enabling battery: Car battery (B1) less than 11,8V or Service battery (B2) less than 10,5V.
This situation generates an alarm that sounds intermittently for 5 seconds. At the same time the display
shows the battery-viewing window with the symbol
-Key beep enabling.
-Enable cleanig glass: confirming with the ENTER key to lock the keys on the panel, come back after 1min.
-Info page: displays the version of the panel "CP" and the shunt "FB"
CONSUMPTION:
To turn on the control panel you must touch for 1 sec. the right side panel where there are the keys.
The panel after 30 sec. switches to standby mode by turning off all symbols except the keys
keys light up when you touch for 1sec. the right side panel.
On stand by (no active controls or back lighting) the control panel with shunt NE185/NE196 consumes a total of approx 41mA.
When the key
is pressed the control panel turns itself off and total consumption is reduced to just 5mA.
If the service battery voltage drops below 10,5V, after 1 minute the control panel turns itself off, together with all live parts. In
this case is advisable to disconnect all loads with the battery main switch and recharge the battery services within 2 days.
WARNING: If the vehicle not in use and the connection 230V is not present, disconnect the battery service with the battery
main switch.
MEMORY BATTERY:
A buffer battery (LITHIUM 3V CR2032) is located on the back of the panel to maintain the time and various program settings in
the event of a power breakdown.
CONNECTIONS:
The back of the panel has a connector for serial connection (JP7), a connector for the external temperature probe (JP5) and a
connector for the internall temperature probe (JP4)
Push button with warning light for turning
PUMP on or off (*)
NE185/NE196
shunt burns out
) repeatedly to enter the page and select the value to
alarm in the tank
alarm in the battery
4
) key to exit the function and save
and those of active loads.
GB