TECHNICAL SPECIFICATIONS

Model
Description
Method of measurement
Mode of operation:
Protection against ingress of water:
Degree of protection:
Measurement range
Measurement pressure:
Pulse value:
Accuracy
Power
Operating conditions
Storage and transportation conditions
Display
Memory
Product dimensions
Product weight
Circumference of arm cuff
Power-off
Accessories
Expected service life of device: about 9 years if calculated by 3 times measurement per day.
Symbols:
Type BF applied part
Warning: The Blood Pressure Monitor JOYCARE was designed to measure blood pressure exclusively in adults.
JC-610 (TMB 995) has been manufactured in compliance with the European directives 93/42ECC 0197
0123
Distributed under the brand JOYCARE, by JOYCARE S.R.L.. sole partner - Via Massimo D'Antona, 28 - 60033 Chiaravalle (AN) - Italy
MADE
IN CHINA
GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO.,LTD.
Zone A, No.105 ,Dongli Road, Torch Development District,Zhongshan,528437,Guangdong,China
MDSS - Medical Device Safety Service GmbH, Schiffgraben 41, 30175, Hannover - Germany.
DISPOSAL The device (including its removable parts and accessories) must not be disposed of together with municipal waste at the end of its life,
but in compliance with European Directive. Since it must be handled separately from household waste, either carry it to a separately-collected
waste disposal centre for electrical and electronic appliances or give it back to the retailer on purchasing a new device with the same purpose. Any
infringement will be severely prosecuted. The batteries used in this device must be disposed of in the special bins at the end of their life.
All the instructions and drawings are based on the latest information available at the time of going to print and may be subject to change.
JC-610 (TMB 995)
Arm blood pressure monitor
Oscillometric
Continuous operation
IP21
Type BF applied part
Rated cuff pressure: 0mmHg-300mmHg (0kPa-40kPa)
40mmHg-230mmHg (5.3kPa-30.7kPa)
(40-199) beat/minute
Pressure: 5°C-40°C within ±3mmHg (0.4kPa)- Pulse value:±5%
appliance powered by internal electric source, 4 AA batteries (included)
DC 6V 1A power pack (not included)
from +5°C to +40°C , humidity ≤ 85%
from -20°C to +60°C , humidity 10% RH~ 93%RH
LCD V.A. 80X60mm
60 measurements with date and time
approx 102x143x73 mm
about 500gr, batteries included
approx. 22~42cm
automatic after around 1 minute unused
arm cuff with tube, instruction manual, 4 "AA" batteries(test batteries are included).
The supplied batteries are for trial use only and they may have a shorter life.
See the documentation attached