Important - Flotec FPX5500 Serie Manual Del Usuario

Bombas centrífugas 50 hz
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Electrical
Max. Load
Motor HP
Volts
1/2
115/230
9.4/4.7
3/4
115/230
12.2/6.1
1
115/230
15.4/7.7
1-1/2
115/230
19.4/9.7
Step 3. Disconnect power before servicing motor or pump. If the discon-
Step 4. Ground the pump permanently using a wire of the same size as that
Step 5. Connect ground wire to a grounded lead in the service panel or to
Step 6. Protect current carrying and grounding conductors from cuts,
Step 7. Connect current carrying conductors to terminals L1 and L2 under
IMPORTANT: 115/230 Volt single phase models are shipped from factory
with motor wired for 230 volts. If power supply is 115 volts, remove motor
canopy and reconnect motor as shown in Figure 3. Do not try to run motor
as received on 115 volt current.
Step 8. Motor has automatic internal thermal overload protection. If motor
Step 9. If this procedure or the wiring diagrams are confusing, consult a
Wiring Chart – Recommended Wire and Fuse Sizes
Branch Fuse
Amp
Rating Amp
15/15
14/14 (1.5/1.5)
20/15
12/14 (2.5/1.5)
20/15
12/14 (2.5/1.5)
25/15
10/14 (4/1.5)
nect switch is out of sight of pump, lock it open and tag it to pre-
vent unexpected power application.
specified in wiring chart. Make ground connection to green ground-
ing terminal under motor canopy marked GRD. or
a metal underground water pipe or well casing at least 10 feet long.
Do not connect to plastic pipe or insulated fittings.
grease, heat, oil, and chemicals.
motor canopy. When replacing motor, check wiring diagram on
motor nameplate against Figure 3. If the motor wiring diagram does
not match either diagram in Figure 3, follow the diagram on the
motor.
has stopped for unknown reasons, thermal overload may restart it
unexpectedly, which could cause injury or property damage.
Disconnect power before servicing motor.
licensed electrician.
DISTANCE IN FEET(METERS) FROM MOTOR TO SUPPLY
0 - 100
101 - 200
(0 - 30)
(31 - 61)
AWG WIRE SIZE (mm
10/14 (4/1.5)
10/14 (4/1.5)
8/14 (6/1.5)
8/14 (6/1.5)
201 - 300
301 - 400
(62 - 91)
(92 - 122)
)
2
10/14 (4/1.5)
6/14 (10/1.5)
8/14 (6/1.5)
6/12 (10/2.5)
6/12 (10/2.5)
6/12 (10/2.5)
6/12 (10/2.5)
4/10 (16/4)
6
.
401 - 500
(123 - 152)
6/12 (10/2.5)
6/10 (10/4)
4/10 (16/4)
4/10 (16/4)