Prepare The Hood Location; Ez1 One-Person Installation - KENMORE ELITE 51293 Manual De Uso Y Cuidado / Instalacion

Campana de cocina
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

NOTE: Before starting installation, read all the steps
of these instructions.
Use the illustration beside to identify your kitchen
cabinet type.
This manual covers 2 kinds of installation: the standard
(without EZ1 brackets) and the EZ1 one-person
installation system (using included template and
brackets). For the standard installation, go to page 14.
EZ1 installation is designed for use with kitchen cabinets that have the same width designation as the range hood
width. If the cabinet is greater than 1/2" wider than the range hood width, please use the standard installation
method.
1. Use the proper template for vertical OR horizontal
disharge (included) for placement of ductwork and
electrical cutout in cabinet or wall. For a non-ducted
installation, DO NOT cut a duct access hole, only cut
the hole for electrical wiring. If replacing a hood and
plan to use the existing duct and electrical, steps 2 to
5 may not be necessary. If so, skip to step 6.
2. Measure and mark the hood center line on cabinet
bottom.
CABINET FRONT
Use this template for marking; do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.
Utiliser ce gabarit pour marquer vos repères; ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l'installation; elles ne doivent pas
être du format exact des conduits.
Use esta plantilla para crear marcados; no trate de cortar el
agujero del conducto a través de la plantilla.
NOTA: To be translated in Spanish.
C
Bend template along graduated
scale when installing to framed
cabinet.
Pour une installation sous une
armoire à fond en retrait, utiliser les
lignes pour mesurer l'épaisseur du
décalage causé par le mur de
l'armoire et plier le gabarit en
conséquence.
To be translated in Spanish.
V RTICAL EX
VERTICAL EXHAUST
C
Place this edge against back wall

PREPARE THE HOOD LOCATION

EZ1 One-person installation system
M
ARK WHERE INDICATED
FOR THE APPROPRIATE SIZE DUCT OPENING
7" R
D
OR
R
D
OUND
UCTING
ECTANGULAR
UCTING
= 3¼" x 10"
= 3¼" x 14"
M
ARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON
LE FORMAT DE CONDUIT UTILISÉ
C
ONDUIT ROND DE
7
PO
OU
C
ONDUIT RECTANGULAIRE
= 3¼ po x 10 po
= 3¼ po x 14 po
T
S
8"
ITLE TO BE TRANSLATED IN
PANISH
C L
C
ONDUCTO REDONDO
O
C
ONDUCTO RECTANGULAR
DE
7
PULG
.
= 3¼ pulg. x 10 pulg.
= 3¼ pulg. x 14 pulg.
7½"
Electrical access hole center
A = single blower hood
B = double blower hood
Centre du trou pour fil
A
A
A
S
d'alimentation électrique
A = hotte ventilateur simple
B = hotte ventilateur double
10½"
To be translated in Spanish
4¼"
Electrical access hole center
A = single blower hood
B = double blower hood
14½"
A
B
C
Appuyer ce bord au mur arrière
Apoyar este borde contra la pared de atrás
C
F
OLD TEMPLATE ALONG GRADUATED
SCALE WHEN INSTALLING TO FRAMED
P
.
CABINET
CENTER LINE
Place this edge against
cabinet bottom.
Appuyer ce bord contre le bas
de l'armoire.
Apoyar este borde contra
la base del armario.
C L
Use this template for marking; do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.
Utiliser ce gabarit pour marquer vos repères; ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l'installation; elles ne doivent pas
être du format exact des conduits.
Use esta plantilla para crear marcados; no trate de cortar el
agujero del conducto a través de la plantilla.
NOTA: To be translated in Spanish.
T T
FRAMED CABINET
3. Align the center line on template with the hood
center line marked on the bottom of the cabinet,
placing the edge (where indicated) of the template
against back wall. When using with framed cabinet
for vertical exhaust installation, fold over rear edge
of template equal to the depth of the cabinet frame
at the wall (use graduations on template, C locations
on template). Tape the template in place.
NOTE: When facing the installation, A and B (on
template) must be at right.
CABINET FRONT
Use this template for marking; do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.
Utiliser ce gabarit pour marquer vos repères; ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l'installation; elles ne doivent pas
être du format exact des conduits.
Use esta plantilla para crear marcados; no trate de cortar el
agujero del conducto a través de la plantilla.
NOTA: To be translated in Spanish.
C
Bend template along graduated
scale when installing to framed
cabinet.
Pour une installation sous une
armoire à fond en retrait, utiliser les
lignes pour mesurer l'épaisseur du
décalage causé par le mur de
l'armoire et plier le gabarit en
conséquence.
To be translated in Spanish.
V RTICAL EX
VERTICAL EXHAUST
C
CENTER LINE
HORIZONTAL
EXHAUST DUCTING
A
B
Electrical access hole center
A = single blower hood
B = double blower hood
Centre du trou pour fil
d'alimentation électrique
A = hotte ventilateur simple
B = hotte ventilateur double
To be translated in Spanish
Electrical access hole center
B
A = single blower hood
B = double blower hood
M
M
ARK WHERE INDICATED
ARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON
FOR THE APPROPRIATE SIZE DUCT OPENING
LE FORMAT DE CONDUIT UTILISÉ
ess hole center
R
ECTANGULAR
D
UCTING
C
ONDUIT RECTANGULAIRE
= 3¼" x 10"
= 3¼ po x 10 po
= 3¼" x 14"
= 3¼ po x 14 po
wer hood
T
ITLE TO BE TRANSLATED IN
S
PANISH
wer hood
C
ONDUCTO RECTANGULAR
= 3¼ pulg. x 10 pulg.
= 3¼ pulg. x 14 pulg.
ELECTRICAL
ACCESS HOLE
LOCATION (B)
(
)
IN WALL
10
FRAMELESS CABINET
VERTICAL
EXHAUST DUCTING
M
ARK WHERE INDICATED
FOR THE APPROPRIATE SIZE DUCT OPENING
7" R
D
OR
R
D
OUND
UCTING
ECTANGULAR
UCTING
= 3¼" x 10"
= 3¼" x 14"
M
ARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON
LE FORMAT DE CONDUIT UTILISÉ
C
ONDUIT ROND DE
7
PO
OU
C
ONDUIT RECTANGULAIRE
= 3¼ po x 10 po
= 3¼ po x 14 po
T
S
8"
ITLE TO BE TRANSLATED IN
PANISH
C L
C
ONDUCTO REDONDO
O
C
ONDUCTO RECTANGULAR
DE
7
PULG
.
= 3¼ pulg. x 10 pulg.
= 3¼ pulg. x 14 pulg.
7½"
Electrical access hole center
A = single blower hood
B = double blower hood
Centre du trou pour fil
A
A
A
S
d'alimentation électrique
A = hotte ventilateur simple
B = hotte ventilateur double
10½"
To be translated in Spanish
4¼"
Electrical access hole center
A = single blower hood
B = double blower hood
14½"
A
B
C
ELECTRICAL
B
ACCESS HOLE
LOCATION (B)
(
)
IN CABINET BOTTOM

Capítulos

Tabla de contenido
loading