3. Remove the screw holding the damper assembly,
remove the tape strip and and put the damper
assembly aside. Save this screws, it will be used later
to hold the blower cover plate
Remove both tape strips holding the 7" round duct
4.
plate, and put the duct plate aside.
5. Remove the parts bag taped in the lower left corner
of the hood.
6. Using a 11/32" nut driver, remove the lock nut retaining
the fl ange of the right blower cover plate (shaded
part on illustration beside to the inner back of hood
(see inset). Remove the right cover plate remaining
retaining screws (6 screws), then set the blower cover
along with its screws and nut aside.
NOTE: Sightly lift up the cover plate before sliding it
towards the left to remove it.
7. Remove the EZ1 brackets from inside the hood by
cutting off the tie wrap. Discard the tie wrap.
8. Remove Electrical Power Cable Knockout from top
(vertical exhaust) or back (horizontal exhaust) of
hood. For knockout removed from back of hood,
install an appropriate strain relief, 1/2" diameter
(not included). For knockout removed from top of
hood, the strain relief will be installed later.
9. Remove 3 screws retaining the recirculation cover plate to the hood. Discard this plate with its screws. Peel
off and discard the membrane (shaded part in illustration below) covering the recirculation grille, ensuring the
openings are totally cleared.
RECIRCULATION
COVER PLATE
.
NON-DUCTED INSTALLATIONS ONLY
SCREWS
8
TAPE
TAPE
PARTS BAG
5
6
7
BACK OF HOOD
LOCK NUT
ELECTRICAL
POWER
CABLE
KNOCKOUT
7" ROUND
DUCT PLATE
1 SCREW
DAMPER
ASSEMBLY
4
3
S
CREW
2
REMOVED IN
1
3
STEP
EZ1
BRACKETS