Anleitung BMS 1000 Quick
Scope of delivery
package
BMS 1000 Quick,
Quick-change drill chuck
1.5 -13 mm,
Additional grip with bit stop
Description
1
Quick-change drill chuck
2 Drill bit stop
3 Additional grip
4 2-speed - gear switch
5 Drilling/hammer drilling -
switch-over
6 Type plate
7 Clockwise, anti-clockwise
rotation - switch-over
8 Speed - control
9 Lock button
10 Operating switch
Technical Data
Voltage
Power
input:
Drilling
Concrete 16 mm
capacity:
Wood 25 mm
speed:
I n 0 :
II n 0 :
Number of
blows:
0-55.100 min
Sound pressure
level
LPA 82 dB(A)
Sound power
level
LWA 92.6 dB(A)
Vibration a w
Weight
Totally insulated
6
07.11.2001 14:23 Uhr
Caution
G The BMS 1000 is not designed
for the operating of auxiliary
devices.
G Do not use near steams or
inflammable liquids.
G Only use sharp bits and suita-
ble screwing bits.
G Remove the plug from the
socket for all adjusting and
cleaning work.
G Protect the mains cable
against any damage. Oil and
acids can damage the cable.
G Do not carry the device by the
mains cable.
G Do not remove the plug from
the socket by pulling the mains
cable.
G Make sure before inserting the
plug that the operating switch
is not locked.
G When using a cable drum
uncoil the cable completely.
Cross-section of wire at least
1,5 mm
230 V
G Do not overload machine.
G Secure all workpieces to be
1000 Watt
processed sufficiently.
G Do not allow children to have
access.
G Make sure you have a secure
Steel 13 mm
stance on ladders or scaffold-
ing when using the drill free-
hand.
0-1100 min
-1
G Localise lines with a line detec-
0-2900 min
-1
tor in walls where power, water
or gas lines are laid invisibly.
-1
G Wear protection goggles and
use a dust mask for dust-pro-
ducing work.
G Always arrange for a qualified
electrician to carry out repairs
G Use only original replacement
parts
10 m/s
2
2,2 kg
Seite 6
2
.
G The level of noise at the work-
place may exceed 85 dB(A). In
this case you will need to intro-
duce noise protection measu-
res for the user. The noise
generated by this electric tool
was measured in accordance
with ICE 59 CO 11, IEC 704,
DIN 45635 Part 21, NFS 31-
031 (84/537/EEC).
G Vibration measured on the
handle acc. to ISO 5349.
Maintenance
G Always keep the drill clean.
G Do not use corroding agents
for cleaning plastic.
G Check carbon brushes in the
case of excessive sparking.
G Keep ventilation channels free.
G If you discover any damage,
you can define spare parts
precisely on account of the
exploded view drawing and
parts list and place your
request with our customer
service.