Cleaning
Strap
Handle
Limit Stop
Screw
Optional Temperature Limiting Adjustment
CAUTION: Risk of personal injury. Scalding may result if the
limit stop is not reinstalled properly.
NOTE: The water temperature does not need to be adjusted if the
water temperature is below 105°F (41°C).
NOTE: Use a thermometer rated for 120°F (49°C) or greater.
NOTE: When using a tempered water supply, install the
vandal-resistant plug button.
For Handle Installations
Turn on the water and adjust to the full hot position by turning
the handle toward the back of the faucet until it stops.
Determine the temperature using a thermometer. If the
temperature exceeds 105°F (41°C), complete the following steps.
Turn the handle until vertical.
Attach the cleaning strap over the sensor.
Remove the handle screw using the supplied 2.5 mm hex wrench.
Remove the handle and the limit stop.
Remove the limit stop from the handle splines.
1046362-5-D
Tab Edge
Plug Button
6
Right Tab
Stop
Setscrew
Kohler Co.