SOLEX
4.
Function and option overview
Description
Volume flow primary circuits
Temperature Bypass
Bypass pump
Sensor-Bypass
Option Bypasspump
Temperature collector
Lower store temperature
Upper store temperature
Temperature feed flow
Temperature feed flow sec.
Temperature return flow
Primary pump
Secondary pump
Antifreeze type
Antifreeze
Store valve
∆T1 on
∆T1 off
∆T2 on
∆T2 off
∆T upper St on
∆T upper St off
∆T upper st nominal
Sensor-Tcol
Option upper store off
Solarisation
CS-Bypass
CS-after-running time
Option CS-Bypass
Tube-init
Tube
Tube collector
Tube-running time
Option tube collector
Tcolmax
∆Tcolmax
Option Col. cooling
Option Recooling
Tcolmin
∆Tcolmin
Type
Range
Basic value
M
0 ... 9999 l/h
M
- 30 ... 250 °C
S
on ... off
P
1 ... 6
P
yes ... no
M
- 30 ... 250 °C
M
- 30 ... 250 °C
M
- 30 ... 250 °C
M
- 30 ... 250 °C
M
- 30 ... 250 °C
M
- 30 ... 250 °C
S
on ... off
S
on ... off
P
Water ... TyfoLS
P
20 ... 70 %
S
on ... off
P
0,0 ... 25,0 K
P
0,0 ... 25,0 K
P
0,0 ... 25,0 K
P
0,0 ... 25,0 K
P
-10,0 ... 10,0 K
P
-10,0 ... 10,0 K
P
40 ... 70 °C
P
1 ... 6
P
yes ... no
M
0 ... 1365 W/m
2
P
100 ... 500 W/m
200 W/m
2
P
0 ... 600 s
P
yes... no
P
00:00 ... 23:59
P
00:00 ... 23:59
P
1 ... 60 min
P
1 ... 600 s
P
yes ... no
P
80 ... 160 °C
P
1 ... 20 K
P
yes ... no
P
yes ... no
P
10 ... 90 °C
P
0,3 ... 10,0 K
Description / Access level
---
---
---
5
no
---
---
---
---
---
---
---
---
Propy.
Water, Propylene, Ethylene oder Tyfocor LS
40 %
---
10,0
7,0
8,0
5,0
5,0 K
3,0 K
60 °C
1
Sensor number for collectors
no
---
solarisation threshold
2
120 s
after-running time for Bypass function
no
08:00
Acceleration time for tube collector function
19:00
End time for tube collector function
30 min
pause between activations
30 s
run time for intitiation
no
110 °C
activation for collector cooling
5 K
hysterisis for collector cooling
yes
no
10 °C
minimum collector limitation
2,0 K
Hysteresis minimum collector limitation
25 |