Parameter Name - Johnson Controls T7200 Serie Instrucciones De Instalación

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
T7200
INSTALLATION INSTRUCTIONS FOR THE TECHNICIAN / FITTER
READ THIS INSTRUCTION SHEET AND THE SAFETY WARNINGS CAREFULLY BEFORE INSTALLING AND
SAVE IT FOR FUTURE USE
REPAIR AND REPLACEMENT
Do not attempt to repair the T7 Series thermostat. In case of an improperly functioning control, contact the nearest Johnson Controls® representative, and
specify the desired product code number. When contacting the supplier for a replacement please state the type/model number of the control located on the
data plate or cover label.
IMPORTANT
• Use this T7 Series Thermostat only as an operating control. Where failure of malfunction of the T7 Series Thermostat could lead to personal injury or
property damage to the controlled equipment or other property, additional precautions must be designed into the system. Incorporate and maintain other
devices such as supervisory or alarm systems or safety or limit controls intended to warn of, or protect against, failure or malfunction of the T7 Series
Thermostat.
• Do not install this thermostat in condensing, wet, or damp environments. Moisture may cause damage to the thermostat.
• Do not remove PCB from the enclosure cover. Removing the PCB from the enclosure cover voids the product warranty.
• Make all wiring connections in accordance with local, nation, and regional regulations. Do not exceed the T7 Series thermostat's electrical ratings.
WARNING
Disconnect power supply before making electrical connections. Contact with components carrying hazardous voltages can cause electrical shock and may
result in severe personal injury or death.
• Risk of Electrical Shock: Ground the thermostat according to local, national, and regional regulations. Failure to ground the thermostat may result in
electrical shock and severe personal injury and death.
• Risk of Electrical Shock and Property Damage: Insulate and secure each unused wire lead before applying power to the thermostat.
Failure to insulate and secure each unused wire lead may result property damage, electrical shock, and severe personal injury or death.
PARAMETER SETTING (PART 1/2)
Press
and
button for 5 seconds at power off mode to get in parameter list. Press M button to scroll the list and use
parameter value.
T7200-
T7200-
Code
TB21-...JS0
TF20-...JS0
01
02
03
04
05
06
07
1
09
2
10
---
2
11
---
2
12
---
13
14
...Continued...
P/N 24-85784-00186 Rev. A_Issue Date: 09 2018

Parameter Name

Application
Upper setpoint limit
Lower setpoint limit
Cooling setpoint unoccupied
Heating setpoint unoccupied
Frost protection
Frost protection setpoint
Fan mode when unoccupied
ECM Min voltage
ECM Max voltage
ECM cut off relay (F-ON)
Restart after power failure
Keypad lock
Default
Function
T7200-TB21-...JS0
00: 2-pipe ON/OFF valve with EC Motor Control
01: 4-pipe ON/OFF valve with EC Motor Control
02: 2-pipe ON/OFF three wire relay valve with EC Motor Control
03: 2-pipe ON/OFF valve with TiO2/ESP relay with EC Motor Control
04: 2-pipe ON/OFF valve with floor heating with EC Motor Control
05: Water source heat pump with EC Motor Control
06: Single fan speed AHU
00
07: 2-pipe Proportional valve, three speed fan
T7200-TF20-...JS0 ON/OFF Control
00: 2-pipe ON/OFF valve
01: 4-pipe ON/OFF Valve
02: 2-pipe ON/OFF three-wire relay valve
03: 2-pipe ON/OFF valve with TiO2/ESP relay
04: 2-pipe ON/OFF valve with floor heating
05: Water source heat pump
35°C
Setting range 2 to 40°C (36 to 99°F)
5°C
Setting range 0 to 38°C (32 to 95°F)
26°C
Setting range 22 to 32°C (72 to 90°F)
18°C
Setting range 10 to 21°C (50 to 70°F)
00: On
00
01: Off
5°C
Setting range 0 to 20°C (32 to 68°F)
00: Low speed
00
01: Set speed
3V
Min voltage below which the fan output is 0%, range 0-10 V. (0.5 V)
10V
Max voltage above which the fan output is 100%, range 0-10 V
00: Disabled
00
01: Enabled
00: Keep last status
00
01: On
02: Off
00: No lock
01: Lock all keys
00
02: Lock the keys except Fan Speed and Temp Adjustment keys
03: Lock the ON/OFF and Timer keys
04: Lock the keys except ON/OFF key
English
and
button to change