Central de mando con microprocesador para portones de tipo batiente
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

MICROPROCESSOR CONTROL UNIT FOR HINGED GATES
INSTRUCTIONS FOR USE - DIRECTIONS FOR INSTALLATION
Thanks to the high-power performance of its built-in microprocessor, this control unit for hinged gates offers a wide
number of services and adjustments. In addition, electronic power control guarantees a high active safety level.
A sophisticated electronic control constantly monitors the power circuit and cuts off the unit if a problems arises
which reduce the operating efficiency of the electronic clutch.
The main settings and operating modes can be defined using dip-switches while time and motor power djustments
are performed using the trimmers installed on the electronic circuit board.
6 built-in LEDS constantly display the status of inputs outputs in addition to any circuit malfunctions.

Power supply

Absorbed power
Max. motor load
Max. load on accessories
Max. electric lock load
Ambient temperature
Protective fuses
Operating logic
Opening / closing time
Pause time
Section opening/closing delay time
Thrust force
Terminal board inputs
Radio control connector
Terminal board outputs
Housing dimensions
Housing degree of protection
3. TERMINAL BOARD M1 (HIGH VOLTAGE) CONNECTIONS - DESCRIPTION
3.1 POWER SUPPLY
Terminals "1 - 2 - 3" (Live - Earth - Neutral), Power supply voltage 230V~ - 50/60Hz.
WARNING: the earth connection is mandatory to ensure proper unit operation.
4. TERMINAL BOARD M2 (HIGH VOLTAGE) CONNECTIONS - DESCRIPTION
4.1 FLASHER
Terminals "4 - 5" (Live - Neutral). Use a flasher with an operating voltage of 230V~(40W max.). When power is
supplied to the system the flasher will blink to confirm that the unit is properly connected to the electric power
supply.
4.2 GEARED MOTOR 1
Terminals "6 - 7 - 8" (Open - Common - Close). Connect the geared motor of section 1 for double section gates. To
be used for geared motor connection only for single-section gates.
WARNING: if the geared motor is incorrectly connected or the connection is not completed, the unit will be inhibited
and this status will be indicated by diagnostic LED 6.
4.3 GEARED MOTOR 2
Terminals "9 - 10 - 11" (Open - Common - Close).
Connect the geared motor of section 2 for double section gates. Do not connect for single-section gates.
Notes:
1)
To install electric cables, us adequate rigid and/or flexible tubes.
2)
Always separate the low-voltage connection cables from the 230V~ power supply cables. Cables for
the power
supply to the equipment must have a 1.5 mm
sheathes.
3)
The box features 4 break-through holes Ø25 where Pg16 cable clamps with minimum protection degree IP54
must be mounted (not supplied).
1. GENERAL FEATURES
2. TECHNICAL FEATURES
Adjustable using trimmer (from 6 to 60 sec.)
Adjustable using trimmer (from 0 to 120 sec.)
Adjustable from trimmer: fixed for opening (0 or 2 sec.);
Single section opening / Complete opening / Closing
photocells / Opening photocells / STOP /
Accessory power supply 24V~ / Flasher / Gate status LED /
Motors / Electric lock / power supply 12V~
5
230 V~ (+6 -10%) - 50/60 Hz.
840 W
2 x 380 W
500 mA
24 W
-20°C to +50°C
4
Step step/Automatic
adjustable for closing (0 to 30 sec.).
Adjustable using trimmer
Power supply + Earth / Antenna
Radio receiver boards
90 x 195 x 250 mm.
IP54
section. To avoid interference, us separate
2
ENGLISH