Guide value for RC selection: R [Ω] ~ 0.2 R
Do not use electrolytic capacitors!

6 Commissioning and Operation

Risk of injury due to uncontrolled actuator movements when the pneumat-
ics are switched on!
There is a danger of personal injury if the system is in an undefined state.
Put the system in a defined state before switching it on.
u
System is operating under pressure!
Incorrect installation could damage the product and cause serious injury.
Before commissioning, check that all connections, ports and maintenance
u
equipment have been correctly installed.

6.1 Commissioning the pressure switch

Proceed as follows to commission the pressure switch:
1. Check whether the pressure switch is mounted correctly (see sec-
tions "g 5. Assembly" and "g 2. Notes on Safety") and make sure that all pres-
sure switch connections are properly connected.
2. Secure the components to be switched to prevent unintentional responses,
and apply voltage.
3. Apply the compressed air to the system.
4. Check that the switch outputs are functioning properly.

6.2 Setting the switching point

See g Fig. 14
Increase the switching point pressure by turning the adjustment screw (1) to the
right (+). Max. torque for adjustment screw 1 Nm.
1. The adjustment screw is self-holding and also remains in the set position with-
out any additional securing, even under unfavorable circumstances.
Reduce the switching point pressure by turning the adjustment screw (1) to
the left (–).
Information on factory settings: see online catalog and name plate.
2. Use an external pressure gauge to check the setting value (switching point).
INFO: The switching point is continuously adjustable, even during operation.
The optimum selection range is when the switching point is in the middle of
the switching pressure range. Optionally, a pressure gauge can be used as an
aid.

7 Service and Repairs

7.1 Cleaning

The product must be cleaned at regular intervals.
• Do not use high-pressure cleaners for cleaning!
• Never use solvents or aggressive detergents!
• Clean the product only with a cloth slightly moistened with water or a mild de-
tergent!

7.2 Maintenance

The product is maintenance-free. In case of technical problems, please contact
one of the addresses found under www.emerson.com/contactus.
AVENTICS™ PM1 | R412018457-BAL-001-AI | English
 [Ω]; C [µF] ~ I
Load
WARNING
CAUTION

8 Disassembly and Exchange

 [A]
Load
Danger of injury if assembled under pressure or voltage!
Assembling when under pressure or electrical voltage can lead to injuries and
damage to the product or system components.
1. Make sure that the relevant system component is not under voltage or
pressure before you assemble the product.
2. Protect the system against being restarted.
1. Make sure that the system is not under voltage or pressure.
2. Release and remove the round plug connector.
3. Loosen the mounting screws on the pressure switch.
4. Remove the pressure switch from the pressure system.

9 Disposal

Dispose of the product in accordance with the national regulations in your coun-
try.

10 Troubleshooting

If you cannot remedy a malfunction, please contact one of the addresses found
under www.emerson.com/contactus.

10.1 Response to malfunctions

If malfunctions occur with unknown causes, exchange the pressure switch
u
with an original pressure switch.
The individual components of the pressure switch cannot be replaced
or repaired.
If you cannot remedy a malfunction, please contact one of the addresses found
under www.emerson.com/contactus.

11 Technical Data

This section contains an excerpt of the key technical data. Further technical data
can be found in the online catalog.
General
Ambient temperature
min. – max
UL application:
Max. ambient tem-
perature
Pneumatics
Medium
Operating pressure
range
Electrics
Operating voltage
min. – max., form A
Operating voltage
min. – max., M12x1
CAUTION
Specifications
-20 – +80°C
+75°C
Specifications
Compressed air in accordance with ISO 8573-1:2010, (max. particle
size: 40 µm; medium dew point: ≤ 3°C; oil content: max. 40 mg/m3)
hydraulic oil
-0.9 – 0 bar / -0.9 – 3 bar / 0.2 – 16 bar
Specifications
12 V – 125 V DC; 12 V – 250 V AC
12 V – 30 V DC/V AC
11