7 Troubleshooting
If the fault you are experiencing is not listed or the recommended action to
be taken does not successfully solve the problem, please remove the battery
and return the power tool to Hilti Service.
Fault
The power tool
doesn't start.
The control switch
cannot be pressed.
Speed of rotation
drops considerably.
The battery is not
heard to engage.
The battery runs low
more quickly than
usual.
Printed: 20.05.2015 | Doc-Nr: PUB / 5230969 / 000 / 00
Possible cause
1 LED blinks: The bat-
tery is empty.
The battery is not fitted
correctly.
1 LED blinks: The bat-
tery is too hot or too
cold.
4 LEDs blink: The power
tool was overloaded
briefly.
The forward / reverse
selector switch is in the
middle position.
Low battery.
The retaining lugs on the
battery are dirty.
Very low ambient tem-
perature.
Action to be taken
▶ Remove the battery
and charge it.
▶ The battery must be
heard to engage.
Remove the battery
and refit it.
▶ Allow the battery to
cool down / warm
up to its working
temperature.
▶ Release the control
switch and press it
again after a few
seconds.
▶ Push the forward /
reverse switch to the
left or right.
▶ Remove the battery
and charge it.
▶ Clean the retaining
lugs.
▶ Warm up the battery
slowly to room tem-
perature.
11