DIP-SWITCH function on
software-programmed systems
Once the software programming is done on a system that is fitted with
one or more LIVI-LS2s, you must set DIP-SWITCH 8 to ON on all the
modules fitted on the system. After performing this operation, each of
the relay-switches contained in the LIVI-LS2 modules can then be soft-
ware-programmed to perform a different function.
Set DIP-SWITCH 8 to ON. DIP-SWITCHES from 1 to 7 are for numbering
the relay-switches contained in each of the modules fitted on the system.
This lets the software identify them during programming.
Position of DIP-SWITCHES
on the separate LIVI-LS2
modules
FG00834M07 - ver. 1 - 09/2017
New number assigned to the module's
on-board relay-switches
Relay-switch 1 becomes Relay-switch 0
Relay-switch 2 becomes Relay-switch 1
Relay-switch 1 becomes Relay-switch 2
Relay-switch 2 becomes Relay-switch 3
Relay-switch 1 becomes Relay-switch 4
Relay-switch 2 becomes Relay-switch 5
Relay-switch 1 becomes Relay-switch 6
Relay-switch 2 becomes Relay-switch 7
Relay-switch 1 becomes Relay-switch 8
Relay-switch 2 becomes Relay-switch 9
Position of DIP-SWITCHES
on the separate LIVI-LS2
modules
This product complies with the law.
Decommissioning and disposal. Dispose of the packaging and the de-
vice at the end of its life cycle responsibly, in compliance with the laws in
force in the country where the product is used. The recyclable components
are marked with a symbol and the material's ID marker.
THE DATA PRESENTED IN THIS MANUAL MAY BE SUBJECT TO CHANGE,
AT ANY TIME, AND WITHOUT NOTICE. MEASUREMENTS, UNLESS OTHER-
WISE STATED, ARE IN MILLIMETERS.
New number assigned to the module's
on-board relay-switches
Relay-switch 1 becomes Relay-switch 10
Relay-switch 2 becomes Relay-switch 11
Relay-switch 1 becomes Relay-switch 12
Relay-switch 2 becomes Relay-switch 13
Relay-switch 1 becomes Relay-switch 14
Relay-switch 2 becomes Relay-switch 15