ENGLISH
General Precautions
Important people-safety instructions: READ CAREFULLY!
•
Make sure that the power supply network, in compliance with the in-
•
stallation rules, is fitted with a two-wait cut off switch, that provides
category III protection levels;
Installing, programming, commissioning and maintenance must only
•
be done by qualified, expert staff and in full compliance with the ap-
plicable law.
Wear antistatic protective clothing when working on the control board.
•
Keep these precautions.
•
Always cut off the mains power when doing cleaning and maintenance
•
jobs.
This product must only be used for its specifically intended purpose.
•
Any other use is dangerous.
The manufacturer declines all liability for any damage as a result of
•
improper, incorrect or unreasonable use.
This device must only be installed inside an electrical panel fitted
•
with a DIN (EN50022) guide fitted with industry standard junction box,
that is accessible only to skilled, qualified technical staff.
Description
Module featuring two relay-switches to user with X1 and X2 series sys-
tems for activating auxiliary services.
The relay-switches can be controlled by door-opening controls or from
receiver-auxiliaries, like the Aux1 and Aux2 buttons etc., or by number
codes typed into the entry panels. The latter is true for those upgraded to
FG00834M07 - ver. 1 - 09/2017
FW 1.06.001 or subsequent versions.
Note: the controls are permanently active whether the system is pow-
ered on or off.
Description of parts
❶ TIMER - The potentiometer regulates the action-duration of one of
the two relay-switches. The time can vary between 1 and 16 seconds.
❷ PROG - The green LED checks the module's programming state.
❸ DIP-SWITCH - This is for programming functions that are associated
with the relay-switches.
Technical data
Type
Maximum consumption (mA)
Consumption in stand-by mode (mA)
Power supply over the BUS line (V DC)
Relay-switches' cut-off power at 250
V with (A) resistive load
Relay-switches' cut-off power at 250
V with (A) inductive load
Storage temperature (°C)
Operating temperature (°C)
LIVI-LS2
30
4
15 to 20
5
2
-25 to 70
0 - 35