When the code is entered correctly, the first parameter appears. The number on the
right consecutive number of the parameter and the number on the left is its value.
The first parameter :00 is the version of the programme code that is purely of
informative nature.
By pressing the right number (the CLOCK field on Figure 13) the next parameter is
displayed.
Installation menu: CODE 1166:
After the installation menu code is entered correctly, the following parameters can be
accessed:
00
programme code version (informative parameter)
21
setting the speed of fan
27
setting low-temperature mode
Setting the speed of the fan (parameter :21)
When the parameter (:21) is selected, press (+) or (-) to set the desired fan speed (40
-100%). On the left side (field 5) the numeric value of the setting is displayed. When
the desired speed of the fan is set, it is stored after a short delay or after pressing
field no. 4.
Setting the low-temperature mode of operation of the heat pump (parameter :27)
When parameter :27 is selected, press (+) or (-) to determine the temperature mode
of operation of the heat pump, which depends on the version of the heat pump. The
low-temperature mode can only be set if the heat pump version allows it!**** On the
left side (TEMP field) the set mode is displayed:
Yes – heat pump version
system includes a 4-way valve
No – heat pump version
include a 4-way valve
Note:
****The low-temperature mode of operation of the heat pump is a setting that the
installer can only set if the version of the heat pump is appropriate. When replacing
the electronic module, the mode of operation must be selected in such a way that it
suits the version of the heat pump!
22
TC
ZNT, heat pump operation mode (up to -7°C), the
TC
Z, heat pump operation mode 7°C, the system does not