ARC 13.56 MHz
Upgradable readers
Installation instructions
- Disconnect the flat flexible antenna cable from connector J6.
- Remove the core from the front part (steps 1, 2).
- Install the core in the keyboard front part.
- Connect the flat flexible antenna cable to connector J6 and the
flat flexible keyboard cable to connector J7.
Disconnect the flat flexible antenna cable of connector J6.
-
- Remove the core from the front part (steps 1, 2).
- Install the core in the screen front part.
- Connect the flat flexible antenna cable to connector J6 and the
screen ribbon to connector J14
-
-
-
-
-
-
STid guarantees the good working order, compliance, technical support and after-sales service of the readers and modules (SE6, SE8, SE8M and SE9) that are
installed as explained below, without any internal or external modifications.
- Check that the cable length that comes out of the module does not exceed 0.39 in. If it
does, push the excess cable into the module housing.
- Connect the cable of the module to connector J9. You should not have a loop
- Insert the module into the reader slot (until you hear a "click" for SE6)
- Cut the base as shown in the drawing
- Place the "reader + module" on the base (i.e. Mounting), use the 2 screws provided with
the module
.
(3)
- Read only readers: Activate the module with configuration card (SCB or OCB).
Slot for the
passage of
the module
cable
(3)
(3)
(1)
STid reserves the right to make change without notice, for the purpose of product improvement.
ARC 13,56 MHz
Lecteurs évolutifs
Notice d'installation
Procedure to change the front part
.
Pass the cables through the hole in the base.
Screw the base in its final location.
Connect the reader.
Test the readings and communication.
Place the reader on the base (clip the top part and then pivot it down).
Lock the reader with the two screws provided using the specific tool.
Procedure to add the biometric (SE6) or 125 kHz module (SE8 / SE8M) or QR Code module (SE9)
.
(2)
Option: Reinforcement plate to rigidify the assembly:
Standard/keyboard reader + module SE6v2: Réf. SE7-ARC-DE-02.
Touch screen reader + module SE6v2: Réf. SE7-ARC-F-02.
Standard/keyboard reader + module SE9: Ref. TOLE-ARC-AQ-BQ-01.
Touch screen reader + module SE9: Ref. TOLE-ARC-CQ-01.
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1097C16 - Page 4 sur 15 - Ed. 30/06/2021
ARC 13.56 MHz
Lectores escalables
Procedimiento de instalación
conforme con NOM-024 -SCFI-2013
- Disconnect the flat flexible antenna cable from
connector J6 and the flat flexible keyboard cable
from connector J7.
- Remove the core from the front part (steps 1, 2).
- Install the core in the screen front part.
- Connect
connector J6 and the flat flexible screen cable to
connector J14
Mounting
(2)
To pass the module cable into
(1)
.
the
support,
preformed part of the support.
the
flat
flexible
antenna
cable
.
cut
out
the
Screw
US
FR
ES
to
loading

Este manual también es adecuado para:

Arcs-x/bf5