ARC1 Mini Mullion reader
MA1 OEM Module
Installation instructions
ARC1-XY
ARC1S-XY/PH5
ARC1S-XY/BT1
Outputs cable: 3 m
A
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC EN 60950-1 Ed2) or type ES1, PS1 (according to IEC EN 62368-1) for the main
supply.
Main power supply:
Max. consumption at 12 Vdc:
Communication:
RS485 (L+ & L-) / TTL (Wiegand / Clock and Data)
Connector output:
- 8 female stamped crimp terminals 28-22AWG (Wurth Electronik 62400113722DEC)
- 8 points female dual-row terminal housing (Wurth Electronik 624008213322)
(use Crimp Hand Tool WURTH ELEKTRONIK 600624228220)
Cable output:
TRANXALARM - 8x0,22mm
Protection:
IP65 level, excluding connectors.
The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (R3x & S3x) or controlled by the remote system with a 0 Vdc
respectively on the "Led 1", "Led 2" and "Buzzer" inputs of the reader's or controlled by the communication protocol of the reader (W3x).
Tearing is detected by an accelerometer. When the reader is wrenched:
•
for R/S 31: the wrenching signal will be emitted on the "Data/Data1" line. This function is configurable via a configuration card.
▪
for R/S 33: the reader will perform the operations configured with the configuration card.
▪
for W33: the reader will perform the operations configured with the SSCP protocol.
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
R and S readers are configurable with the SCB configuration card or virtual configuration card created with SECard.
▪
If the SCB is compatible with the reader's firmware, the LED lights green and the buzzer beeps five times.
▪
If the SCB is not compatible with the reader's firmware, the LED lights red and the buzzer is activated for 1 s.
Caution: set your reader with your own company key.
On power-up, the reader enters an initialization phase:
1. Activation of the white LED and buzzer for 100 ms.
For read-only readers:
2. Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.
3. For serial R/S reader only: the orange LED flashes 20 times: waiting for an update.
4. For ARC1S / MA1S Blue only: Activating white fixed LED during Bluetooth initialization.
5. Activation of the default LED (flashes blue if no customer specific configuration).
▪
Caution: at the reader Bluetooth (BT1) powering, make sure that nothing is in an area of at least 10 cm / 3.94 in. around the reader (ex. No
hand in front of the reader...).
Connection
- Press the orange part to open.
- Insert the wire.
- Release the orange part.
- Check that the wire is correctly cliped
▪ The supply voltage at the reader's connector should be between +9 Vdc and +15 Vdc.
▪ As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference, depending on their radiation level
and the proximity of the reader.
▪ Recommended distance between two readers: parallel plane: 15.8 in – same plane: 15.8 in – perpendicular plane: 11.8 in.
▪ Recommended distance between two Blue readers: 2 meters either plan.
▪ Readers installed on a metal surface may have reduced performances.
▪ Use a ferrite (two-way) for the cable (power supply and data). Example: reference 74271222 WURTH ELEKTRONIK.
▪ By design, the reader can be installed indoors and outdoors.
▪ Disconnect the wires or the connector of the reader BEFORE powering on or off.
▪ Operating temperature: -4 °F to 158 °F / -20°C à +70°C.
For data signals, 10k pull-up resistors are connected internally to V
STid reserves the right to make change without notice, for the purpose of product improvement.
Lecteur Etroit ARC1
Module OEM MA1
Notice d'installation
MA1-XY
MA1S-XY/PH5
MA1S-XY/BT1
B
Range: +9 Vdc to +15 Vdc
ARC1-XY: 130 mA
ARC1S-XY /PH5: 140 mA
MA1-XY: 130 mA
MA1S-XY /PH5: 140 mA
– Length 3.05m
2
Read-only reader configuration
Host
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1110A08- Page 1 sur 6 - Ed. 03/12/2020
Product references
X:
1: TTL Output
3: RS485 Output
Connector Output cable
4
5
2
1
6
3
8
7
Power supply characteristics
Typical: 12 Vdc
Characteristics
Buzzer / LED
Anti-tearing
Powering-up the readers
Caution for Bluetooth reader
TBLOCK option
Precautions for installation
TTL pull-ups
(power supply voltage) for optimal wiring distances.
in
Lector Estrecho ARC1
Módulo OEM MA1
Procedimiento de instalación
conforme con NOM-024 -SCFI-2013
Y:
A: cable
B: cable with connector
Type
Clock &
Wiegand
Data
Brown
0 Vdc
Red
+Vcc (+9 Vdc to +15 Vdc)
Grey
D0
Code
Blue
D1
Data
Yellow
Clock
Clock
Green
Led 1
Orange
Led 2
White
Buzzer
ARC1S-XY /BT1: 150 mA
MA1S-XY /BT1: 150 mA
➔Reader
US
FR
ES
RS485
NC
L+
L -