Troubleshooting
Troubleshooting
Problem
The unit switches
off.
The unit cannot
be switched on.
Charger:
no charging
process (red
continuous light).
Charger:
Fault
(red flashing light).
If in doubt, always visit a service centre. Switch the unit off before doing any work and remove the battery.
Spare parts and accessories
Order no.
196-119-650
196-120-650
196-121-650
Delivery via your dealer
Warranty
The warranty regulations issued by our company or the importer are valid in all countries.
Your unit will be repaired free of charge under the warranty, provided the cause was a material or manufac-
turing fault. In the event of a claim under the warranty, please contact your dealer or nearest branch office.
Operating instructions for leaf blower
Possible cause
The battery is too hot (over 45 °C).
The battery is flat.
The battery is flat.
The battery is defective.
The contacts are dirty.
The battery has not been inserted
correctly.
The battery temperature is outside
5 °C to 45 °C.
The battery is defective.
Article designation
LI-ION POWER Pack ABP 36-03
LI-ION POWER Pack ABP 36-05
LI-ION POWER CHARGER ABC 36-03
Remedial action
Leave the battery to cool down.
Recharge the battery.
Recharge the battery.
Replace the battery.
Clean the contacts.
Insert the battery correctly into the battery
charger.
Leave the battery to cool down
or warm up.
Replace the battery.
Article description
Battery 36 V/3 Ah
Battery 36 V/5 Ah
Rapid charger 36 V/3 A
English