5
Use of extension cords
Using extension cords
WARNING
A damaged supply cord presents a hazard! Do not touch the supply cord or extension cord if damaged
while working. Disconnect the supply cord plug from the power outlet.
▶ Check the appliance's supply cord at regular intervals and have it replaced by a qualified specialist if
found to be damaged.
•
Use only extension cords of a type approved for the application and with conductors of adequate gauge
(cross section). The power tool may otherwise suffer a drop in performance and the extension cord may
overheat.
•
Check the extension cord for damage at regular intervals.
•
Replace damaged extension cords.
•
When working outdoors, use only extension cords that are approved and correspondingly marked for
this application.
Information on recommended minimum conductor cross-sections and cable lengths is accessible via
a link, in the form of a QR code, at the end of this document.
6
Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
6.1
Positioning the sanding pad
Power tool, sanding pad and backing pad together form a system. Be sure to use the correct
combination and settings for the application.
The choice of sanding pad (grit size), speed and contact pressure determines the stock removal rate
and the finish.
1. Unplug the supply cord from the power outlet.
2. Select a suitable sanding pad and secure it to the backing pad. Make sure that the sanding pad is
centered and securely seated against the backing pad.
7
Types of work
WARNING
Damaged power cords are a safety hazard! If the supply cord or extension cord is damaged while work
is in progress, immediately disconnect the device and the cord from the electricity supply. Do not touch the
damaged part of the cord.
▶ Regularly check all supply cords. Replace defective extension cords. Have damaged power cords
replaced by a qualified specialist.
Use of a ground fault circuit interrupter (residual current device, RCD) with a maximum tripping current of
30 mA is recommended.
7.1
Switching on
▶ Press the on/off button.
▶ The multi-purpose LED shows green.
Warning! The power tool develops torque as soon as the motor starts.
If possible, always use the power tool in combination with an industrial vacuum cleaner.