Fitting A Remote Control Receiver Card; Control Leds - Genius LYNX 03 Instrucciones Para El Uso

Tabla de contenido
4.3.2 S
tart
Terminals "17-21". The status of this input is signalled by the START LED. Any device (e.g. push-button, radio control, etc.)
can be connected to this circuit. By closing a contact, the circuit generates a pulse for total opening and/or closing
of gate. Its operating mode is set by dip-switch 5.
To connect several pulse generators, connect the devices in parallel.
4.3.3 C
P
loSing
hotoCellS
Terminals "18-21". The status of this input is signalled by the FTC LED. Any safety device (e.g. photocells, safety edge,
etc.) can be connected to this circuit. By opening a contact, the circuit protects closing motion.
• If safety devices are not connected, fit a jumper at input.
• To install several safety devices, connect the NC contacts in series.
4.3.4 S
toP
Terminals "19-21". The status of this input is signalled by the STP LED. Any device (e.g. push-button, pressure switch, etc.)
can be connected to this circuit. By opening a contact, the circuit stops gate movement. The set cycle will restart
only if a successive opening or closing pulse is received.
• If STOP devices are not connected, fit a jumper at input.
• To install several STOP devices, connect the NC contacts in series.
4.3.5 o
P
Pening
hotoCellS
Terminals "20-21". The status of this input is signalled by the FTO LED. Any safety device (photocells, safety egdes, etc.)
can be connected to this circuit, which, by opening a contact, has a safety effect on the opening motion.
• If no safety devices are connected, fit a jumper at input.
• To install several safety devices, connect the NC contacts in series.

5. FITTING A REMOTE CONTROL RECEIVER CARD

The control unit is designed to house a 5-pin radio-receiver module. Installation procedure: turn off power and fit the
module on connector M5 inside the control unit.
To avoid damaging the receiver and thus irreparably jeopardising its operation, the receiver must be fitted while
observing the direction specified in paragraph 9 (Connection lay-out).
This done, observe the receiver instructions on memory storage of the remote control. When the remote control has
been stored, it acts just like any command device on START.
LED
POWER - power supply
FCA – opening limit-switch
FCC – closing limit-switch
CLOSE
START
FTC – closing safety device
STP - stop
FTO – opening safety device
LED status shown in bold when automated system closed and control unit powered.

6. CONTROL LEDS

LIGHTED
Mains power
Disengaged
Disengaged
Engaged
Engaged
Disengaged
Disengaged
Disengaged
10
OFF
No power or batteries
Engaged
Engaged
Disengaged
Disengaged
Engaged
Engaged
Engaged