we recommend checking the following at least
twice a year:
1. Non-return valves, filters and replaceable
cartridge: de-scale or replace worn or damaged
parts.
2. Mixing chamber: de-scale.
If the PREMIX is not mixing correctly (fig. E):
• Balance the pressure. The pressure differential
between the hot water and the cold water must
be less than 1 bar.
• Check the hot water temperature. The
temperature should be higher than 50°C.
• Shut off the water supply.
• Check that the filters
correctly. Replace if necessary.
• Check the non-return valves
necessary.
• The water supply must be connected using nuts
with a compacted flange or a flat faced tap
connector.
• To remove the mechanism:
- Unscrew the outlet nipple
spanner.
- Remove the spring
- Remove the water guide
- Remove the thermostatic element and the
shuttle
by hand.
• Clean the thermostatic element and the shuttle
• Clean the mixer body interior.
• Check the O-ring.
• Replace the mechanism. Turn on the water
supply. Always carry out a cold water failsafe
check after dismantling or carrying out
maintenance.
After Sales Care and Technical Support:
For Delabie UK Ltd market only:
Tel. +44 (0)1491 824 449
For all other markets:
Tel. +33 (0)3 22 60 22 74 email: [email protected]
The most recent version of this installation guide
is available on: www.delabie.com
have been installed
. Replace if
using a 33 mm
.
.
.
Tabla de contenido
loading

Tabla de contenido