Mains Connection - SFA Sanicondens Mini v02 Manual De Funcionamento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
Connecting the discharge pipe
The Sanicondens® Mini discharge connection must be connected to a flexible vinyl hose (with inner
diameter = 10 mm):
- Insert the hose into the discharge connection that has a built-in non-return valve (fig. 5).
- Position the flexible hose in the upmost vertical position possible to avoid any kinking. It is recommended to make a
smooth turn to avoid the hose from kinking.
- Secure the hose by using a clamp (fig. 5).
The Sanicondens® Mini is fitted with a non-return valve to prevent re-activation.

3.3 MAINS CONNECTION

Connect the power cable B to the Sanicondens® Mini (fig. 6) and then to the main power. Comply with local installation
requirements.
3.4 USE
Functional test
Before turning on the pump, make sure you remove the protective lock pin from the rear of the
device. See fig. 4.
- Pour water into the tank.
- Check that the pump starts and stops when the water level drops.
- Check that there are no leaks in the connections.
Sanicondens® Mini is ready to use. Example of an installation of a Sanicondens® Mini: see pg. 6.
STANDARDS
4
Sanicondens® Mini conforms to the European directive on low voltage.
INTERVENTIONS
5
Disconnect electrical supply before working on the unit!
5.1 MAINTENANCE
This device does not require any special maintenance.
5.2 TROUBLESHOOTING
Fault detected
The pump doesn't start.
The pump does not lift.
GUARANTEE
6
Sanicondens® Mini is guaranteed for 2 years for parts and labour, subject to correct installation and use of the unit.
INSTRUCTIONS INTENDED SOLELY FOR QUALIFIED PROFESSIONALS
Probable causes
The pump is not connected to the power supply.
The lock pin has not been removed.
The unit is not leveled.
Power outage.
Float blocked.
Condensates inlet pipe blocked.
Noon-return valve blocked.
Discharge pipe blocked.
Plug in the unit.
Remove the lock pin.
Check the unit with a leveling tool.
Check the main power.
Clean the tank.
Clean the inlet pipe.
Clean the valve.
Clean the discharge pipe.
13
EN
Action needed
Tabla de contenido
loading

Tabla de contenido