AREA OF APPLICATION

1
Sanicondens® Mini is a pump used to lift condensation water from an air conditioning system, a condensation
boiler, dehumidifiers or from refrigeration units. If necessary, insert a neutralisation device (see your boiler
manufacturer's instructions). The use of a neutraliser is mandatory on oil boilers in order to preserve the
pump.
The pump starts automatically and has a high level of performance, safety and reliability as long as all the
installation and maintenance instructions mentioned in this manual are strictly followed.
All applications other than those described in this manual are prohibited.
DESCRIPTION
2
2.1 OPERATING PRINCIPLE
Sanicondens® Mini contains a pump. The tank of the SANICONDENS® Mini has a built-in a float which controls
the operation of the motor. When the condensate enters the tank, the pump starts up.
2.2 TECHNICAL DATA
Type
Max. vertical pumping
Maximum flow rate
Min. pH
Level ON/OFF
Voltage
Frequency
Current consumption
Power rating
Electrical class
2.3 LIST OF PARTS SUPPLIED See pg. 6.
2.4 DIMENSIONS See pg. 8.
2.5 PERFORMANCE CURVES See pg. 8.
2.6 VERTICAL PUMPING/HORIZONTAL PUMPING See pg. 8.
START UP
3
3.1 INSTALLATION
Always install the pump:
– horizontally, using a leveling tool,
– as close as possible to the appliance keeping in mind that the condensate has to drain through gravity into the
pump.
To ensure proper ventilation of the motor, the pump must be free of any obstruction.
The pump can be mounted against a wall: see fig. 1 and 2.
Check that the Sanicondens® Mini is leveled: fig. 2.
3.2 HYDRAULIC CONNECTION
Connecting the inlet
The pump has two inlets Ø28 mm that can be used as required (fig. 3):
– The left inlet is open.
– The right inlet is protected by a break-off plug. To use the right inlet, first cut out the cut-off plug with a cutter and
remove it.
Drain the condensate water to any of these inlets (fig. 4). If necessary, use a rubber flexible adapter A.
CD 10
Protection index
4.5 m
Sound level
380 L/h
Average operating temperature
2.5
Maximum allowable temperature
56 mm / 46 mm
220-240 V
Weight of the unit
50 Hz
Tank volume
0.52 A
Supply cable
60 W
Max. power for the connected boiler gas: 50 kW / oil: 30 kW
I
Wall mounting
12
IP20
< 45 dBA
35°C
80°C
S3 15% (1min30 ON/8min30 OFF)
2 kg
2.2 L
1.5 m
Yes