4. INSTRUCTIONS FOR THE END USER
The instructions contained in this section are for unqualified personnel.
4.1 INITIAL OPERATION
4.1.1 DESCRIPTION OF THE ELECTRONIC CONTROL PANEL
�
�
�
�
�
�
�
AUX
Turns ON / turns OFF
FNC
Exit function
SET
Machine status menu (short pressure), parameter programming menu ( extended pressure )
DOWN
Go through the menu voices, decreases the values
DEFROST/UP
Activate defrost / go through the menu voices, increase the values
DISPLAY
Display parameters values, breakdowns codes and temperature
COMPRESSOR
Lighted for active cold / blinking for delay, protection or activation blocked
DEFROST
On for ongoing defrost / blinking for manual activation
FAN
Lighted for evaporator fans in function
AUX
Lighted for active output
ECO
Lighted for set-point inserted is displayed, blinking when reduced setpoint is displayed.
ALARM
Lighted for active alarm / blinking for tacit alarm
4.1.2 STARTING THE MACHINE
Press the button for 2 seconds. A few minutes after the switch has been enabled, the compressor will begin to operate.
4.1.3 TEMPERATURE SETTING
The machine operation is fully automatic in that the manufacturer has already set the "set point" temperature (cold room tempe-
rature). To change this setting, proceed as follows:
1) PRESS two times the SET button: the current setting for the "set point" temperature will then be displayed.
2) SELECT the desired temperature setting for the cold room from within the limits pre-defined by the manufacturer.
3) CHANGE the set point setting by pressing the UP button to increase the value and the DOWN button to decrease it.
Once the setting has been changed press the SET button once more.
�
�
NOTE
Always keep closed the plastic cover!
�
�
�
78