Input impedance: 10 MΩ for small ranges.
Frequency range: 40 Hz to 1000 Hz.
Overload protection: Same as CD voltimeter.
Average value (rms sine wave).
Measuring amperage
Protection against overchange: 2A/250 V fuse.
Maximum current range: 20 A max. 15s.
Voltage loss: 200 mV.
DC AMPERIMETER
Range
200 μA
2 mA
20 mA
200 mA
2 A
20 A, 20 μA
Protection against overchange: 2A/250 V fuse.
Frequency range: 40 Hz to 1000 Hz.
Maximum current range: 20 A max. 15s.
Voltage loss: 200 mV.
Resolution
0.1 μA
1 μA
10 μA
100 μA
1 mA
10 mA, 10 μA
Accuracy
± (0.8% ± 1 digit)
± (1.2% ± 1 digit)
± (2.0% ± 5 digits)