Troubleshooting; Wearing Parts - Freeman PFL618BR Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MODEL: PFL618BR
!
WARNING:
Disconnect the tool from the air source
whenever clearing a jam. After
disconnecting the tool from the air
compressor, there should still be enough
air pressure to fire the tool. After the air
hose is disconnected, always fire the tool
into scrap wood repeatedly to make sure
all of the compressed air is expended.
Drive Guide(H)
Bolts(I)
MAINTENANCE
!
WARNING:
Any time inspection, maintenance, and
cleaning are done:
◆Disconnect the tool from the air
source.
Empty the magazine completely.
ANTI-DUST CAP
Each tool is packed with an anti-dust cap on the air
connector, check it after unpacking. Keep the anti-
dust cap to cover the air connector when the tool is
not in use to prevent the dust.
.
08
HTTP://WWW FREEMANTOOLS COM
LUBRICATION
Frequent, but not excessive, lubrication is required
for best performance. Oil for the tool added through
the air line connection add will lubricate the internal
parts. Do not detergent oil or additives as these
lubricants will cause accelerated wear to the seals
and bumpers in the tool, resulting in poor tool
performance and frequent tool maintenance.
CAUTION:
Lubricate tool only with specified
lubricants.
CLEA ING
N
Avoid using solvents when cleaning plastic parts.
Most plastics are susceptible to damage from
various types of commercial solvents and maybe
damaged by their use. Use clean cloths to remove
dirt, dust , oil, grease, etc.
!
WARNING:
Do not at any time let brake fluids,
gasoline, petroleum-based products,
penetration oils, ect. come in contact
with plastic parts. Chemicals can damage,
weaken or destroy plastic which may
result in serious personal injury.
COLD WEATHER OPERATION
For cold weather operation, near and below freezing,
the moisture in the air line may freeze and prevent
tool operation. We recommend the use of air tool
lubricant or permanent antifreeze (ethylene glycol)
as a cold weather lubricant.
CAUTION:
Do not store tools in a cold weather
environment to prevent frost or ice
formation on the tools' operating valves
and mechanisms that could cause tool
failure.
.
1-888-669-5672
MODEL: PFL618BR
RECOMMENDED HOOKUP
CAUTION:
The air compressor must be able to
maintain a minimum of 70psi when the
tool is being used. An inadequate air
supply can cause a loss of power and
inconsistent driving.

TROUBLESHOOTING

PROBLEMS
POSSIBLE CAUSES
Air leaking in head cap.
⒈Loose screws.
⒉Worn or damaged O-rings or seals.
Lack of power.
⒈Tool is too dry.
Slow to cycle.
Air pressure too low.
Exhaust blocked.
Not shooting fasteners .
⒈Damaged pusher spring.
Wrong size of fasteners.
Fasteners are
⒈Drive channel is worn.
jammed in the tool
Piston is broken or worn.
frequently.
Bent fasteners.
Dirty magazine.
Loose magazine.
Wrong fasteners.
!
WARNING:
Use only Freeman Authorized Repair Parts. For questions please call 1-888-669-5672 or visit
our website at http://www.freemantools.com

WEARING PARTS

Repair parts can be ordered from our website: http://www.freemantools.com
.
HTTP://WWW FREEMANTOOLS COM
!
WARNING:
Do not connect with an air compressor
which can potentially exceed 200psi. As
tool may burst, possibly causing injury.
CORRECTION ACTIONS
⒈Tighten screws.
Install overhaul kit.
⒈Add about 2-3 drops of
lubrication into the air connector.
⒉Make sure the air compressor
is set between 70psi and 110psi.
Clean exhaust channel.
⒈Replace spring.
⒉Use 1/2" crown staples or
1-1/2" to 2" nails.
⒈Fix the drive channel.
Replace the piston.
Remove the bent fasteners,
replace with the 1/2" crown
staples or 1-1/2" to 2" nails.
Clean magazine.
Tighten screws.
Verify that fasteners are the
correct size.
.
1-888-669-5672