Install The Receptor Tray, And Connect The Drains - Kohler K-1913 Guia De Instalacion

Ocultar thumbs Ver también para K-1913:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Drain Line
Pulley
Assembly
Receptor Tray
Install, route and secure
accumulator drain line
to receptor tray.
Approximately
1/4" (6 mm)
clearance required
from receptor tray.

12. Install the Receptor Tray, and Connect the Drains

All Installations
Install the drain to the receptor tray following the drain manufacturer's instructions.
When Reassembling the Receptor:
NOTE: These steps are not required if the receptor tray was not removed in a previous step. If the
receptor tray is already assembled, go to "All Installations" below.
Carefully move the receptor tray into position, rotating it up and in.
Make sure the subfloor cutout is large enough to prevent any contact with the backside of the receptor at
or near the drain.
Reconnect the receptor tray to the frame using the existing holes and the screws that were removed
previously.
1128532-2-G
Clamp
Cable
2-1/2" (64 mm) Minimum Air Gap
Tie
Install drain and attach to receptor tray.
Board
Strainer Body
Water Inlet
Nut and O-Ring
Drain Valve
22
Accumulator
Drain Line
Kohler Co.