SIMPLIFIED INSTRUCTIONS FOR K800 24V FAST WITH L1 24V-CRX
1° Connecting the accessories
COMMON
A+TEST / A-
24Vdc 0,5A ±15%
PHOTOCELL AUTO-TEST
OR ENERGY SAVING
(LOW BATTERY)
WITH BATTERY
24Vdc 0,5A ±15%
OPERATION
OPEN
CLOSE
SINGLE COMMAND
PEDESTRIAN
TIMER
COMMON
COMMON
STOP
PHOTOCELL 1
PHOTOCELL 2
EDGE 1
EDGE 2
ANTENNA
BRAIDING
RUN TRIMMER - high-speed regulator
For gates weighing from 0 to 200 kg is recommended to set the RUN trimmer from 1/2 to MAX.
For gates weighing from 200 to 400 kg is recommended to set the RUN trimmer from MIN to 1/2.
LOW SP TRIMMER - slow speed approach regulator
Adjustment is performed to determine the correct speed at the end of opening and closing according to the gate or when there is friction that might cause the system to function poorly.
TCA TRIMMER - AUTOMATIC CLOSING pause time regulator for TOTAL or PEDESTRIAN openings
This trimmer makes it possible to adjust the pause time for total or pedestrian automatic closing. Only with gate completely open (total) or partially open (pedestrian) and LED DL11 ON (trimmer
rotated clockwise to activate the feauture).
The pause time (for a totally opened gate) can be adjusted from a minimum of 2 s up to a maximum of 2 minutes.
TRIMMER SENS - impact sensor regulator
With this trimmer it is possible to adjust the impact reaction:
- with trimmer turned fully counter-clockwise and DL15 OFF, impact sensor deactivated.
- with trimmer at minimum, the impact reaction occurs after 3 seconds (low sensitivity)
- with trimmer at halfway, the impact reaction occurs after 1.5 seconds (medium sensitivity)
- with trimmer at max, the impact reaction occurs after 0,4 seconds (high sensitivity)
3° Installing and adjusting the limit plate cams
Position the cams on the rack.
Tighten the two screws to lock them. How to finely adjust cam intervention
is explained below.
K FCM
ITA
ESP ENG FRA GRE DEU RUS ARA THAI BUL FAR TUR
24 Vdc 3 W
24 Vdc 20 W
LED
ANTENNA
433 MHz
MANUAL RELEASE
L.S. OPEN
AND CLOSE
SAFETY
M
BACKUP BATTERIES
FOR BATTERY CHARGER BOARD (OPTIONAL)
Release the motor (turn the key counter clockwise until the limit is
reached without forcing) and move the gate by hand
Check when the cams are activated.
Note: The cams must press the electric microswitches before the mobile
part touches the mechanical stops.