Note: If pilot does not stay lit, refer to
Troubleshooting, pages 19 though 21.
Also contact a qualified service technician
or gas supplier for repairs. Until repairs
are made, light pilot with match. To light
pilot with match, see Manual Lighting
Procedure, page 19.
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. If control
knob does not pop up when released,
contact a qualified service technician or
gas supplier for repairs.
Ignitor Button
IGNITOR
20,000 BTU/Hr Heaters
Control Knob
OFF
OFF
OFF
20,000 BTU/Hr
Heaters
Figure 18 - Burner Patterns
18
OPERATION
Control Knob
Figure 17 - Control Knob in the OFF Position
Control Knob
OFF
OFF
OFF
OFF
30,000 BTU/Hr Heaters
www.usaprocom.com
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute before
lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The main burner
should light. Set control knob at LOW,
MED or HIGH locked positions.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Ignitor Button
IGNITOR
OFF
30,000 BTU/Hr Heaters
Control Knob
Thermocouple
Ignitor Electrode
Figure 19 - Pilot
Pilot Burner
200317-01E