5. Package contents
1 Millo / Millo pro dental arch trimmer
1 Cutter, tapered 6-blades (coarse),
NOT suitable for plastic models.
1 Allen key
1 Operating instructions
1 Grounded wall plug
(No. 1805-0000 only)
6. Models
1804-0000
Millo, 230 V, 50 / 60 Hz
1804-1000
Millo, 120 V, 60 Hz
1805-0000
Millo pro, 230 V, 50 / 60 Hz
1805-1000
Millo pro, 120 V, 60 Hz
8. Troubleshooting
Problem
Unit does not
operate after
switching it on.
Unit switches
off during
operation.
Heavy dust
accumulation
on the work
table.
Cause
• Mains cable not
plugged in.
• No electricity supply to
the mains socket.
• Unit connected to
an extractor that is
switched off.
• Motor fuse triggered,
as the motor tempera-
ture is too high.
• Fuse triggered.
• Extractor not used.
• Extraction power too
low.
7. Accessories
No. 1806-0001 Cutter, conical cross-cut
No. 1806-0002 Cutter, tapered 6-blades
No. 2921-0050 Silent TS, 230 V, 50 / 60 Hz
No. 2921-1050 Silent TS, 100 - 120 V,
No. 90003-4305 Universal hose connector
No. 2926-0000 Y-junction
No. 15-0823
• Plug in the mains cable.
• Check the mains socket.
• Check the extractor, refer to the extrac-
tor instructions if necessary.
• Unplug the unit and allow it to cool for
approx. 1.5 hrs.
• Use an extractor (see Section 1.3).
• Switch on the safety cut-out / replace
fuse (see Section 3.3).
• If the fuse triggers again, return the
unit for repair.
• Use an extractor (see sect. 1.3).
• Check the filter of the extractor.
• Check that the suction hose is not
bent.
• Check that the suction hose is fitted
securely to the connector
(D, Figure 2, 4).
• Use a higher extraction setting.
- 5 -
(fine)
(coarse), NOT suitable for
plastic models.
50 / 60 Hz
adapter
PVC Flex super elastic
suction hose (sold by the
metre)
Remedy