Uline H-6513 Manual Del Usuario página 9

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

LOCATING YOUR SERIAL NUMBER
Your serial number can be found on a white label on the right side cover of your heater. It will begin with 2 digits, the
letter "H" followed by 6 digits. For Example: 13H123456. Have your serial number ready before calling Uline Customer
Service.
OPERATING ISSUE
Heater ignites, but main PCB
shuts off after a short period
of time. Lamp flickers and
LED display shows "E1."
Heater will not operate
or motor runs for a short
time. Lamp flickers and LED
display shows "E1."
Fan does not operate
when heater is plugged in
and power switch is in the
on position. The lamp is
flickering and/or LED display
shows "E1" or "E2."
Lamp is flickering and LED
display shows "E3."
Poor combustion and / or
excess soot production.
Heater does not turn on and
the lamp is not lit.
PAGE 9 OF 27
TROUBLESHOOTING
CAUSE
Incorrect pump pressure.
Dirty input, output or lint filter.
Dirty fuel filter.
Nozzle is dirty.
Photocell lens is dirty.
Photocell not installed properly.
Photocell is defective.
Improper electrical connection between
main PCB and photocell.
No kerosene in the fuel tank.
Incorrect pump pressure.
Corroded spark plug or incorrect plug gap.
Dirty fuel filter.
Dirty nozzle.
Moisture in fuel tank.
Improper electrical connection between
transformer and circuit board.
Ignitor wire not connected to spark plug.
Defective ignitor.
Thermostat is set too low.
Broken electrical connection between
main PCB and motor.
Thermostat switch has failed.
Dirty input, output or lint filter.
Dirty fuel filter.
Poor quality of fuel.
PSI is too high or too low.
Temperature limit sensor has overheated.
No electrical power.
Fuse is blown.
Improper electrical connection between
temperature limit sensor and circuit
board.
1-800-295-5510
Adjust pump pressure.
Clean or replace air or lint filter.
Clean or replace fuel filter.
Clean or replace nozzle.
Clean or replace photocell.
Adjust photocell position.
Replace photocell.
Check wiring connections. (See wiring diagram on page 8)
Fill tank with fresh kerosene.
Adjust pump pressure.
Clean or replace spark plug. Adjust plug gap as necessary.
Clean or replace fuel filter.
Clean or replace nozzle.
Rinse fuel tank with clean, fresh kerosene.
Inspect all electrical connections. (See wiring diagram on page 8)
Re-attach ignitor wire to spark plug.
Replace ignitor.
Rotate thermostat to a higher setting.
Inspect all electrical connections.
(See wiring diagram on page 8)
Replace thermostat switch. (See wiring diagram on page 8)
Clean or replace air or lint filter.
Clean or replace fuel filter.
Flush fuel tank and refuel heater.
Use proper pressure.
Push power switch to off and allow heater to cool for 10
minutes. Restart heater.
Check power cords for proper connection and test the power
supply.
Check and replace the fuse.
Inspect all electrical connections.
(See wiring diagram on page 8)
uline.com
RECOMMENDATIONS
0521 IH-6513
Tabla de contenido
loading

Este manual también es adecuado para:

H-6514

Tabla de contenido