H-5780
INFRARED HEATER
CEILING MOUNT
Optional
Mounting Bracket
C
B
NOTE: For indoor (excluding residences) and
outdoor applications.
WARNING! EXPLOSION AND FIRE HAZARD!
Serious injury or death may occur.
WARNING! ELECTRICAL SHOCK HAZARD! Serious
injury or death may occur.
• Disconnect from electrical supply before
installing or servicing this heater.
• Reflector end caps must be installed prior to
powering the unit; refer step 3.
CAUTION! Install heater so that the quartz tube
is horizontal. Failure to do this may cause the
heating element within the tube to sag and
cause premature burnout.
Each heater is equipped with two high-temperature
silicone lead wires and a ground termination. Make sure
power source conforms to the heater requirements.
Only use quartz tube included with heater.
1.
Insert quartz tube into L-shaped slots in heater housing.
2. On each end of the quartz tube, place one lead
wire ring terminal, one lock washer and one hex nut
on the threaded stud and tighten securely.
(See Figure 1) Lock washers and hex nuts are
provided in the hardware package.
PAGE 1 OF 9
1-800-295-5510
uline.com
SPECIFICATIONS
6' Cord Set Exits
End of Heater
(not shown)
A
QUARTZ TUBE INSTALLATION
Housing
Finish
Reflectors, End Caps
Suspension
Voltage
Cord Set Plug
Matching Receptacle
• Do not use in locations containing hazardous
atmospheres.
• Do not use inside residences.
NOTE: Use a second wrench to hold the inner hex
nut in place while tightening the outer hex nut.
CAUTION! Failure to securely tighten this
connection will cause the element to fail
prematurely.
Figure 1
Quartz Tube
3. Attach reflector end caps to both ends of housing
using the four screws provided in the hardware
package.
Para Español, vea páginas 4-6.
Pour le français, consulter les pages 7-9.
24 ga. Galvannealed
Brown Powder Coat
0.04" Gold Anodized Aluminum
Adjustable Mounting Bracket or Chain
120V
NEMA 5-15P
NEMA 5-15R
Hex Nut
Lock Washer
Ring Terminal
0421 IH-5780
Tabla de contenido
loading

Resumen de contenidos para Uline H-5780

  • Página 1 Para Español, vea páginas 4-6. Pour le français, consulter les pages 7-9. H-5780 1-800-295-5510 uline.com INFRARED HEATER CEILING MOUNT SPECIFICATIONS Housing 24 ga. Galvannealed Finish Brown Powder Coat Optional 6' Cord Set Exits Mounting Bracket Reflectors, End Caps 0.04" Gold Anodized Aluminum...
  • Página 2 HEATER INSTALLATION WARNING! FIRE HAZARD! Serious injury or death Figure 2 may occur. Adjustable Mounting Brackets • Read and follow clearances shown below for 3" 3" all heater installations. • Do not use inside residences. 6.5" MINIMUM INSTALLATION CLEARANCES 3.5" 0º...
  • Página 3 2. Increase mounting height or distance. close. Hot spot in tube 1. Heater is not level. 1. Adjust to a level mount. 2. Grease or moisture on tube. 2. Clean tube. Replace if problem persists 1-800-295-5510 uline.com PAGE 3 OF 9 0421 IH-5780...
  • Página 4: Calentador Infrarrojo - Instalación En Techo

    H-5780 800-295-5510 uline.mx CALENTADOR INFRARROJO - INSTALACIÓN EN TECHO ESPECIFICACIONES Galvanizado Recocido de Calibre 24 Carcasa El Set del Cable de 6' Sale Acabado Pulvirrevestido Café Soporte de por el Extremo del Calentador Montaje Opcional Reflectores, Aluminio Anodizado Dorado de 0.04"...
  • Página 5: Instalación Del Calentador

    INSTALACIÓN DEL CALENTADOR ¡ADVERTENCIA! ¡PELIGRO DE INCENDIO! Puede Diagrama 2 provocar lesiones serias o la muerte. Soportes de Montaje Ajustables • Lea y siga todos los requisitos que se muestran 7.6 cm 7.6 cm a continuación para la instalación de cualquier (3") (3") calentador.
  • Página 6: Mantenimiento

    1. El calentador no está nivelado. 1. Ajuste el montaje para nivelarlo. un punto determinado. 2. Hay grasa o humedad en el tubo. 2. Limpie el tubo. Reemplácelo si el problema persiste. 800-295-5510 uline.mx PAGE 6 OF 9 0421 IH-5780...
  • Página 7: Appareil De Chauffage Infrarouge - Installation Au Plafond

    H-5780 1-800-295-5510 uline.ca APPAREIL DE CHAUFFAGE INFRAROUGE – INSTALLATION AU PLAFOND SPÉCIFICATIONS Boîtier Galvanisé de calibre 24 Cordon de 1,8 m (6 pi) Support de Finition Revêtement poudré brun sort par l'extrémité de l'appareil fixation facultatif de chauffage (non illustré) Réflecteurs, embouts...
  • Página 8 INSTALLATION DE L'APPAREIL DE CHAUFFAGE AVERTISSEMENT! RISQUE D'INCENDIE! Une Figure 2 blessure grave ou la mort peuvent s'ensuivre. ARRÊT Supports de fixation réglables • Lisez et respectez les distances de 7,6 cm 7,6 cm dégagement indiquées ci-dessous pour tout (3 po) (3 po) type d'installation de l'appareil de chauffage.
  • Página 9: Dépannage

    1. L'appareil de chauffage n'est pas de niveau. 1. Ajustez l'installation pour qu'il soit de niveau. dans le tube. 2. Présence de graisse ou d'humidité sur le tube. 2. Nettoyez le tube. Remplacez si le problème persiste. 1-800-295-5510 uline.ca PAGE 9 OF 9 0421 IH-5780...