Meter Functions – Resistance (Ω)
IMPORTANT: If you are testing an application that has capacitors in the
circuit, be sure to turn the power OFF on the test circuit and discharge all
capacitors. Accurate measurement is not possible if external or residual
voltage is present.
Resistance " Ω"
Select the
Resistance "Ω"
Select the
note, the unit defaults to resistance.
Insert:
 Black lead in COM terminal.
Ω
 Red lead in V-
-RPM terminal.
Touch the test lead probes across the resistor to be tested.
Meter Functions –Diode Check (
IMPORTANT: Turn the power OFF to the test circuit
Select the Diode Check "
function with the rotary switch and
mode button.
Insert:
Black lead in COM terminal.
Ω
Red lead in V-
-RPM terminal.
Touch the Black test probe to the negative (-) side of the diode.
Touch the Red test probe to the positive (+) side of the diode. Reverse the probes: Black to
the positive
(+) side and Red to the negative (-) side.
Note:
A "good" diode will read low in one `direction and high in the other direction when the
probes are reversed (or vice versa).
A defective diode will have the same reading in both directions or read between 1.0 to 3.0 V.
in both directions