before the high) temperature measurements are made.
This is a result of the cooling process which must take place for the IR sensor.

General Specifications

Response rate
Operating Temperature
Operating Humidity
Power Supply
Weight
Size
Infrared Thermometer Specifications
Range
Output
Accuracy
Emissivity
Field of View
Laser power
Spectral response
BATTERY REPLACEMENT
① As battery power is not sufficient, LED show will " ON " replacement with one new battery type 9V is required.
② Open battery cover, then take out the battery from instrument and replace with a new 9-Volt battery and place the battery
cover back.
General Specifications
General Specifications
The instrument complies with: IEC 1010-1 EN61010-1.
Insulation: Class2, Double insulation.
Overvoltage category: CATIII1000V/CATIV600V.
Display: 4000 counts LCD display with function indication.
Polarity: Automatic, (-) negative polarity indication.
Overrange: "OL" mark indication.
Low battery indication: The "BAT" is displayed when the battery voltage drops below the operating level.
Measurement rate: 2 times per second, nominal.
0.5 second approx.
32°F to 122°F (0°C to 50°C)
Max. 80% RH.
9V battery
182g
164 x 50 x 40mm
o
-30 to 550
C/-22 to 1022
o
o
1mV=1
C or 1
F
o
± 2% of reading or ± 4
F (2
Note: Accuracy is specified for the following ambient temperature range: 64 to 82°F
(18 to 28°C)
0.95 fixed value
D/S = Approx. 8:1 ratio (D = distance, S = spot)
(Has 90% encircled energy at the focal point)
Less than 1mW
6 to 14 µm (wavelength)
o
F
o
C) whichever is greater.