Idiomas disponibles

clean the vertical (condenser) coil, contact Service for
instructions.
To reassemble, follow the above steps in reverse. Be
sure to reinstall heat exchange block in the original
orientation. When installing the rear cover, carefully
thread the pump hose through the hole in the back
pocket before putting the cover in place.

TROUBLESHOOTING

F A U L T
Water drips out
when moving unit
Unit does not
operate
Unit operating,
but room not dry
Unit collects too
little water
If the problem you are experiencing is not listed here, call your local distributor or contact
our Service Department at 800-932-3030 for further assistance.
SPECIFICATIONS
LGR 2800i #110128
Model
(F410)
Use weight
156 lbs. | 70.8 kg
Dimensions
40.5 × 23 × 24 in.
(H × D × W)
103 × 58 × 61 cm
8.0 amps,
Power
120 volts
Water removal
130 pts. | 61.5 liters /
AHAM (80°F/60%
day
RH)
Water removal max.
200 pts. | 94.6 liters /
(90°F/90% RH)
day
Water removal
20 pts. | 9.5 liters /
80°F/20% RH
day
400 CFM | 679.7
Max process air
CMH*
33°F–125°F
Operating range
1°C–52°C
Construction
Rotomolded shell
ETL certified to CSA
Safety
22.2 no. 92
Specifications are subject to change without notice. Some values may
be approximate. *Automatic variable speed for optimized
performance.
110489Q #110128 (F410), #110133 (F411)
C A U S E
Unit was unplugged before
purging was complete.
Unit not switched on.
No power to machine.
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Room air is dry.
Room temperature is too low.
Filter is full.
Coils are clogged.
LGR 3500i #110133
(F411)
158 lbs. | 71.2 kg
40.5 × 23 × 24 in.
103 × 58 × 61 cm
11.2 amps,
120 volts
170 pts. | 80.4 liters /
day
240 pts. | 113.6 liters
/ day
24 pts. | 11.4 liters /
day
400 CFM | 679.7
CMH*
33°F–100°F
1°C–38°C
Rotomolded shell
ETL certified to CSA
22.2 no. 92
NOTICE: Rubber strips are attached to the outside
edges of the evaporator and condenser coils to
provide an airtight seal around the heat exchange
block. When reinstalling the block, make sure the
seals are in place and are not kinked or folded.
S O L U T I O N
Purge unit before moving. See "At the End of the Job."
Switch unit on.
Plug in unit; check power cord connection at wall outlet and at
base of unit.
Make sure "Humidistat" is OFF.
Allow more time for drying.
Increase air movement with air movers.
Seal off area to reduce infiltration.
Make sure "Humidistat" is OFF.
Confirm humidity level with hygrometer.
Increase room temperature.
Check filter. Replace as necessary.
Check coils. Clean as necessary.
PARTS INCLUDED
40 ft. (12 m) of drain hose with quick-connect fitting.
25 ft. (7.6 m) detachable power cord.
4-PRO air filter. Reorder #121708 (F584) 24 pk.
ACCESSORIES
VMax Adaptor #100694 (F422)
Sto&Go Ducting #113260 (F405)
FOR PARTS AND SERVICE CALL YOUR LOCAL
DISTRIBUTOR or Dri-Eaz at 800-932-3030. Visit
warranty.LegendBrandsRestoration.com and register
your purchase to ensure you receive any important
product releases.
WARNING: This product may expose you to
chemicals, including lead and phthalates, known
to the State of California to cause cancer, birth defects,
or other reproductive harm. For more information, go to
P65Warnings.ca.gov
8
Legend Brands, Inc.
Tabla de contenido
loading

Este manual también es adecuado para:

Lgr 3500i110128110133

Tabla de contenido