Gallagher S400 Instrucciones página 12

Ocultar thumbs Ver también para S400:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
• Install solar energizers on a post above the ground.
• Keep the solar panel clean (e.g. from dirt) periodically use a soft cloth with
water and a mild detergent.
• Test voltage on the fence using a Gallagher Fence Volt Meter (G50301).
• Turn energizer off before handling fence or battery connections.
Symptom
Battery
indicator is
solid red
Battery
indicator
flashes red
Fence
Voltage
indicator
flashes red
No voltage
on fence
10
3E4097 Gallagher S400 Solar Energizer User Manual
Problem
Battery capacity is
low due to insufficient
sunlight. The energizer
will slow down to use
less power and allow
batteries to charge.
No batteries,
incorrect batteries are
connected or batteries
are damaged.
Output voltage is too
low, due to a high load
on the fence line.
Energizer may have
been damaged by
lightning.
Solutions
Ensure energizer is getting enough
sun.
Turn energizer off for 3 days leave
in sun to charge batteries.
Remove battery and use a 12 V 1.2A
charger to charge battery.
Connect the correct batteries.
Replace both batteries.
Check batteries are OK using the
battery check function.
Check fence and earth system for
faults.
Check energizer isn't faulty;
disconnect from fence and earth
measure across fence and earth
terminals with a Gallagher Fence
Volt Meter
-
if less than 5 kV return
energizer for service
-
if more than 5 kV the fault is
with the fence or earth system.
Tabla de contenido
loading

Este manual también es adecuado para:

G361404

Tabla de contenido