GB
6. POSSIBLE PROBLEMS
PROBLEM
POSSIBLE CAUSES
The pump switches
Leaks in the system.
on
and
off
continuously.
Dry
stop
even
if
Operating
there is water in the
high.
suction pipe.
The pump do not
1.Mains voltage failure.
start again.
2.The drop between the
Fluomac and one of the tap
is too great.
3.The pump is out of order.
4.Fluomac is
malfunctioning.
The pump does not
1.There are big leaks in the
stop.
system.
2.Fluomac is
malfunctioning.
7. TECHNICAL DATA
Power source: . . . . . . . . . . . . . . . . . . .
Max. current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 A
Operating pressure range: . . . . . . . . . . . .. .. 1÷3,5 bar / 14.5÷50,65 psi
Pre-set operating pressure: ................................... 1,5 bar / 21,8 psi
Max. allowable pressure: . . . . . . . . . . . . . . . . . . . . . . . . 10 bar / 145 psi
Max. liquid temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . .55° C/130° F
Pressure Drop to 100l/min: . . . ... . . . . . . . . . . . . . . . . . . . .... . . .0,7bar
Connections: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . 1" GAS male
Protection level: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP 54
Type (Re. EN 60730-1): .......................................................... 1.B
SOLUTION
Check
all
connections.
pressure
too
Turn
screw
anticlockwise
direction.
Press
RESET button and make
sure the red light is off
when the pump stops.
1.Check
the
connections.
2.Turn
screw
clockwise (+) to increase
the operating pressure.
3.Consult an electrician.
4.Consult your dealer.
1.Check the system.
2. Consult your dealer.
110-230 VAC ±10% 50/60Hz
hydraulic
6
(-)
the
electrical
6
in