Centerline
2. Install Electrical Service
DANGER: Risk of electrical shock. Connect only to a
properly-grounded, grounding-type receptacle which is
protected by a GFCI or RCD. Do not remove the grounding
pin or use a grounding adapter.
NOTICE: The Canadian Electric Code requires receptacles installed
in bathrooms to be located at least 1 meter from a bathtub or
shower if practical, but in no case less than 500 mm. If the
installation is in Canada, install this unit in accordance with the
Canadian Electrical Code, Part 1.
A licensed electrician should install a properly-grounded,
grounding-type receptacle which is protected by a Class A GFCI
or RCD.
The receptacle should be located 6" (15.2 cm) above the floor line,
and 3" (7.6 cm) to the right of the closet flange centerline.
The toilet electrical cord is 36" (91.4 cm) long.
1092035-2-A
3"
(7.6 cm)
GFCI or RCD-
Protected Receptacle
6" (15.2 cm)
4
Kohler Co.