Oase HeatUp 25 Instrucciones De Uso página 8

Ocultar thumbs Ver también para HeatUp 25:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

- EN -
• Route the power connection cable such that it
forms a drip loop!
• Switching on: Connect the unit to the mains. The
unit switches on immediately.
• Switching off: Disconnect the unit from the mains.
Checking the temperature values
NOTE
• The heater switches on and off automatically in
order to maintain the set temperature.
• A light in the glass bulb indicates that the heater
is functioning.
• The light and heater are switched off when the
set temperature is reached.
How to proceed:
• When the unit has been operating for about one
day, check the water temperature with a precision
thermometer.
• The measured temperature is lower than the set
temperature: Check the water flow around the
unit and, if necessary, move the unit to a different
position where the water circulation is not
obstructed by e.g. plants
• Measure the temperature again after some time.
• The temperature difference is still too great:
Calibrate the unit. (-> Calibrating the unit)
• The measured temperature is higher than the set
temperature: Calibrate the unit. (-> Calibrating the
unit)
Calibrating the unit
• Calibration range: It is possible to calibrate the
unit by plus 6 °F and minus 6 °F.
• The calibration controller protrudes out of the
8
HeatUp 25/50/100/150/200/300
Tabla de contenido
loading

Este manual también es adecuado para:

Heatup 50Heatup 100Heatup 150Heatup 200Heatup 300

Tabla de contenido